MuxOneNAND2G(KFM2G16Q2A-DEBx)

 

 

 

 

 

 

 

 

 

 

FLASH MEMORY

 

MuxOneNAND4G(KFN4G16Q2A-DEBx)

 

 

 

 

 

 

 

 

 

 

2.7.5 External Memory Spare Area Assignment

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Buf.

Word

Byte

F

E

D

C

B

A

 

9

8

 

7

6

 

5

 

4

3

2

 

1

0

 

 

Address

Address

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

8000h

10000h

 

 

 

 

 

 

 

 

 

BI

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

8001h

10002h

 

 

 

 

 

Managed by Internal ECC logic

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

8002h

10004h

 

 

Reserved for the future use

 

 

 

 

 

Managed by Internal ECC logic

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BootS 0

8003h

10006h

 

 

 

 

 

Reserved for the current and future use

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

8004h

10008h

 

ECC Code for Main area data (2nd)

 

 

 

ECC Code for Main area data (1st)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

8005h

1000Ah

 

ECC Code for Spare area data (1st)

 

 

 

ECC Code for Main area data (3rd)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

8006h

1000Ch

 

FFh(Reserved for the future use)

 

 

 

ECC Code for Spare area data (2nd)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

8007h

1000Eh

 

 

 

 

 

 

 

 

Free Usage

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

8008h

10010h

 

 

 

 

 

 

 

 

 

BI

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

8009h

10012h

 

 

 

 

 

Managed by Internal ECC logic

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

800Ah

10014h

 

 

Reserved for the future use

 

 

 

 

 

Managed by Internal ECC logic

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BootS 1

800Bh

10016h

 

 

 

 

 

Reserved for the current and future use

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

800Ch

10018h

 

ECC Code for Main area data (2nd)

 

 

 

ECC Code for Main area data (1st)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

800Dh

1001Ah

 

ECC Code for Spare area data (1st)

 

 

 

ECC Code for Main area data (3rd)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

800Eh

1001Ch

 

FFh(Reserved for the future use)

 

 

 

ECC Code for Spare area data (2nd)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

800Fh

1001Eh

 

 

 

 

 

 

 

 

Free Usage

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

8010h

10020h

 

 

 

 

 

 

 

 

 

BI

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

8011h

10022h

 

 

 

 

 

Managed by Internal ECC logic

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

8012h

10024h

 

 

Reserved for the future use

 

 

 

 

 

Managed by Internal ECC logic

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DataS

8013h

10026h

 

 

 

 

 

Reserved for the current and future use

 

 

 

 

 

 

 

0_0

8014h

10028h

 

ECC Code for Main area data (2nd)

 

 

 

ECC Code for Main area data (1st)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

8015h

1002Ah

 

ECC Code for Spare area data (1st)

 

 

 

ECC Code for Main area data (3rd)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

8016h

1002Ch

 

FFh(Reserved for the future use)

 

 

 

ECC Code for Spare area data (2nd)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

8017h

1002Eh

 

 

 

 

 

 

 

 

Free Usage

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

8018h

10030h

 

 

 

 

 

 

 

 

 

BI

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

8019h

10032h

 

 

 

 

 

Managed by Internal ECC logic

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

801Ah

10034h

 

 

Reserved for the future use

 

 

 

 

 

Managed by Internal ECC logic

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DataS

801Bh

10036h

 

 

 

 

 

Reserved for the current and future use

 

 

 

 

 

 

 

0_1

801Ch

10038h

 

ECC Code for Main area data (2nd)

 

 

 

ECC Code for Main area data (1st)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

801Dh

1003Ah

 

ECC Code for Spare area data (1st)

 

 

 

ECC Code for Main area data (3rd)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

801Eh

1003Ch

 

FFh(Reserved for the future use)

 

 

 

ECC Code for Spare area data (2nd)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

801Fh

1003Eh

 

 

 

 

 

 

 

 

Free Usage

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

- 51 -

Page 51
Image 51
Samsung KFN4G16Q2A, KFM2G16Q2A warranty External Memory Spare Area Assignment, Buf