MuxOneNAND2G(KFM2G16Q2A-DEBx)

FLASH MEMORY

MuxOneNAND4G(KFN4G16Q2A-DEBx)

Program Operation Flow Diagram

Start

 

Select DataRAM for DDP1)

 

Add: F101h DQ=DBS*

 

Write Data into DataRAM2)

 

ADD: DP DQ=Data-in

 

Data Input

NO

Completed?

 

YES

 

Write ’DFS*, FBA’ of Flash

 

Add: F100h DQ=DFS*’, FBA

 

Write ’FPA, FSA’ of Flash

 

Add: F107h DQ=FPA, FSA

 

Write ’BSA, BSC’ of DataRAM

 

Add: F200h DQ=BSA, BSC

 

* DBS, DFS is for DDP

Write 0 to interrupt register3)

Add: F241h DQ=0000h

Write ’Program’ Command

Add: F220h

DQ=0080h or 001Ah

Wait for INT register low to high transition

Add: F241h DQ[15]=INT

Read Interrupt register

Add: F241h DQ[6]=WI

DQ[6]=1?

YES

Read Controller

Status Register

Add: F240h DQ[10]=Error

DQ[10]=0?

YES

Program completed

NO

Read Controller

Status Register ‘Lock’ bit high

 

Add: F240h DQ[14]=Lock

Program Lock Error

NO

Program Error

*: If program operation results in an error, map out the block including the page in error and copy the target data to another block.

NOTE :

1)DBS must be set before data input.

2)Data input could be done anywhere between "Start" and "Write Program Command".

3)‘Write 0 to interrupt register’ step may be ignored when using INT auto mode. Refer to chapter 2.8.18.1

During the execution of the Internal Program Routine, the host is not required to provide any further controls or timings. Furthermore, all com- mands, except a Reset command, will be ignored. A reset during a program operation will cause data corruption at the corresponding location.

If a program error is detected at the completion of the Internal Program Routine, map out the block, including the page in error, and copy the target data to another block. An error is signaled if DQ10 = "1" of Controller Status Register(F240h) .

Data input from the Host to the DataRAM can be done at any time during the Internal Program Routine after "Start" but before the "Write Pro- gram Command" is written.