17. TROUBLESHOOTING

17 - 1 TROUBLESHOOTING

￿In order to prevent electric shock and short circuit, be sure to turn power off before performing work.

￿Be careful so as not to damage wirings. Damaged wiring can cause electric shock or short circuit.

￿After removing the cause of the functioning of the Circuit Protector, reinstate the Circuit Protector. Depending on the cause of the functioning, using the Circuit Protector as is without removing the cause can cause generation of heat and fire hazard.

In case a problem occurs, first check wiring connector connections.

TABLE 17 a

PROBLEMS

CAUSE

COUNTERMEASURES

 

 

 

When the main SW is

The power is not ON.

Firmly insert the plug into the outlet.

turned ON, the machine

 

 

Incorrect power source/voltage.

Make sure that the power supply/voltage are correct.

is not activated.

 

 

 

 

The CIRCUIT PROTECTOR

After eliminating the cause of overload, have the Circuit

 

functioned due to momentary

Protector of the AC Unit restored.

 

overcurrent.

(See Section 6 and Next page)

 

 

 

 

The fuse of the connect board was

After eliminating the cause of overload, replace the

 

blown out due to momentary

specified rating fuse (514-5036-7000, FUSE 6.4 ø X 30

 

overcurrent.

7000mA 125V). (PHOTO 17. 1 b)

 

 

 

The color on the PTV

Screen adjustment is not

Make adjustment appropriately. (See Section 14)

screen is not correct.

appropriate.

 

 

 

 

PTV screen has a color

Affected by the periphery, such as

Make convergence adjustments. (See Section 14)

deviation.

other machines, location building's

 

Change installation direction/ position.

 

steel frames, etc.

 

 

 

 

 

Move the other machines which cause the problem.

 

 

 

No PTV screen image.

Connector connection fault.

Check connector connection between the PTV and Cabinet.

 

 

(See Section 6)

 

 

 

Sound is not emitted.

Sound volume adjustment is not

Adjust the SWITCH UNIT's sound adjustment volume

 

correct.

control. (See 9 - 1)

 

 

 

 

Malfunctioning BD. and Amp.

Perform SOUND TEST. (NAOMI Service Manual)

 

 

 

During game play, the

Circuit Protector functioned due to

After eliminating the cause of overload, have the power

Compressor does not

momentary overload.

supply Circuit Protector restored. (PHOTO 17. 1 b)

operate.

 

 

 

 

 

During game, the Ride does

Saftety Sensor functioned.

Remove the foreign article.

not operate.

 

 

Air Tank Cock is closed.

Open the Cock. (See 11-1)

 

 

 

 

 

Preset pressure is incorrect.

Make pressure adjustment. (See 10-4)

 

 

 

 

Air leakage.

Check the Air Drive System.

 

 

 

 

Communication fault between the

Check in the wiring test. (See 9-3g)

 

Main BD and the I/O BD.

 

 

 

 