Sega WaveRunner owner manual 17 2 Error Message, Display Network Error no Master Site Cause, Slave

Models: WaveRunner

1 182
Download 182 pages 51.97 Kb
Page 110
Image 110

17 - 2 ERROR MESSAGE

￿This work should be performed by the Location's Maintenance Man or Serviceman. Performing work by non-technical personnel can cause accidents.

￿Should any errors other than listed by this manual or by NAOMI Service Manual occur, contact where the product was purchased from or an office described in this manual. Failing to comply with this instruction can cause accidents.

This product displays the error on the screen if the faulty is detected. If an error is displayed, be sure to take action against it according to the appropriate cause and countermeasures listed below.

It may be displayed the error other than listed by this manual or by NAOMI Service Manual. In that case, contact where the product was purchased from or an office described in this manual without operating it selfishly.

DISPLAY

NETWORK ERROR: NO MASTER SITE

CAUSE

No MASTER setting in Communication Mode.

COUNTERMEASURES

Perform the Communication Mode setting in the Game Assign-

 

ments. Set one of the machines to MASTER and all others to

 

SLAVE. (9-3 d) (20-3)

DISPLAY

NETWORK ERROR: DUPLICATE MASTER SITE

CAUSE

MASTER setting is duplicated in Communication Mode.

COUNTERMEASURES

Perform the Communication Mode setting in the Game Assign-

 

ments. Set one of the machines to MASTER and all others to

 

SLAVE.

DISPLAY

NETWORK ERROR: NO SLAVE SITE

CAUSE

No SLAVE setting in Communication Mode.

COUNTERMEASURES

Perform the Communication Mode setting in the Game Assign-

 

ments. Set one of the machines to MASTER and all others to

 

SLAVE. (9-3 d) (20-3)

DISPLAY

NETWORK ERROR: TOO MANY NODES SITE

CAUSE

Too many machines are connected.

COUNTERMEASURES

Up to 4 machines can be connected to allow to enjoy communica-

 

tion play.

DISPLAY

NETWORK ERROR: DUPLICATE CABINET ID

CAUSE

The number of Cabinet ID is duplicated in Communication Mode.

COUNTERMEASURES

Change the number of Cabinet ID for every seat in the Game As-

 

signments. (9-3 d) (20-3)

DISPLAY

DRIVE BD ERROR: E2H

CAUSE

The Ride is not centering with the right value.

COUNTERMEASURES

Ensure that the Ride is slanted or the connector of ASSY Wire

 

Tube is connected securely. (Section 6)

101www.seuservice.com

Page 110
Image 110
Sega WaveRunner 17 2 Error Message, Display Network Error no Master Site Cause, Slave, Display Drive BD Error E2H Cause