CIRCUIT PROTECTOR and FUSE REPLACEMENT
In case fuse replacements other than those stated in this manual are necessary, contact where you purchased the product from for inquiries regarding this matter.
Fuse replacements other than those specified can cause accidents and are strictly forbidden.
In order to prevent an electric shock, be sure to turn power off and unplug from the socket outlet before performing work by touching the internal parts of the product.
Be careful so as not to damage wirings. Damaged wiring can cause electric shock and short circuit accidents.
Be sure to use fuses meeting specified rating. Using fuses exceeding the specified rating can cause fire and electric shock accidents.
After eliminating the cause of the blowing of fuse, replace the fuse. Depending on the cause of fuse blowing, continued use with the fuse as is blown can cause generation of heat and fire hazard.
Remove the 2 truss screws and dismount the lower lid from the front cabinet. The fuse and the circuit protector for the air drive are installed on the ASSY PWR SPLY unit inside the front cabinet.
PHOTO 17. 1 a
TRUSS SCREW,black
M4 X 25
LOWER LID
FUSE 7
CIRCUIT
PROTECTOR
PHOTO 17. 1 b