TABLE 17 b

PROBLEMS

CAUSE

COUNTERMEASURES

 

 

 

During game, the Ride does

Deviation of Handle Volume.

Adjust the Volume value in the test mode. (See 9-3e)

not turn when the

 

 

 

Replace the Volume. (See 12-2)

Handlebars are turned.

Malfunctioning of Handle Volume.

 

 

 

When gripping the Throttle

Deviation of Throttle Volume.

Adjust Volume values in the Test mode. (See 9-3e)

Lever, the Ride does not

 

 

 

Replace the Volume. (See 12-1)

advance.

Malfunctioning of Throttle

 

Volume.

 

 

 

 

Vertical movements of the

Initial setting is wrong.

Turn power off and then turn it back on again to perform

Ride during game is weak

 

initial setting movement. (See 6 Section 6)

and irregular.

 

 

Malfunctioning of Pitch Volume.

Replace Volume. (See 11-3)

 

 

 

 

 

Preset pressure is incorrect.

Make pressure adjustment. (See 10-4)

 

 

 

 

Air leakage.

Check the Air Drive System.

 

 

 

 

Communication fault between the

Check in the wiring test. (See 9-3g)

 

I/O BD and Drive BD.

 

 

 

 

 

Air Damper adjustment fault.

Air Damper adjustment. (See the end of this Section)

 

 

 

Left/right movements of the

Deviation of Roll Volume.

Adjust Volume values in the Test mode. (See 9-3e)

Ride is weak and irregular.

 

 

Preset pressure is incorrect.

Make pressure adjustment. (See 10-4)

 

 

 

 

 

Air leakage.

Check the Air Drive System.

 

 

 

 

Communication fault between I/O

Check in the wiring test. (See 9-3g)

 

BD and Drive BD.

 

 

 

 

 

Malfanctioning of Inclination

Replace the Inclination Sensor. (See 11-4)

 

Sensor.

 

 

 

 

Communication play not

Communication cable connection is

Connect the communication cables correctly. (See 20-2)

possible.

incorrect.

 

 

 

 

 

Communication settings are wrong.

Correct the settings. (See 20-3)

 

 

 

Fluorescent lamp doesn't

Connector connection fault.

Check connector connections between the Billboard and

light up.

 

PTV. (See Section 6)

 

 

 

 

Fluorescent lamp need replacement.

Replace the fluorescent lamp. (See Section 15)

 

 

 

CIRCUIT PROTECTOR

CIRCUIT PROTECTOR

Functions due to the activation of bimetal. To restore the function, wait for approximately one minute or longer until the bimetal cools off. (Press the Button.)

www.seuservice.com

98

Page 107
Image 107
Sega WaveRunner owner manual Circuit Protector