TABLE 17 b
PROBLEMS | CAUSE | COUNTERMEASURES | |
|
|
| |
During game, the Ride does | Deviation of Handle Volume. | Adjust the Volume value in the test mode. (See | |
not turn when the |
|
| |
| Replace the Volume. (See | ||
Handlebars are turned. | Malfunctioning of Handle Volume. | ||
|
|
| |
When gripping the Throttle | Deviation of Throttle Volume. | Adjust Volume values in the Test mode. (See | |
Lever, the Ride does not |
|
| |
| Replace the Volume. (See | ||
advance. | Malfunctioning of Throttle | ||
| Volume. |
| |
|
|
| |
Vertical movements of the | Initial setting is wrong. | Turn power off and then turn it back on again to perform | |
Ride during game is weak |
| initial setting movement. (See 6 Section 6) | |
and irregular. |
|
| |
Malfunctioning of Pitch Volume. | Replace Volume. (See | ||
| |||
|
|
| |
| Preset pressure is incorrect. | Make pressure adjustment. (See | |
|
|
| |
| Air leakage. | Check the Air Drive System. | |
|
|
| |
| Communication fault between the | Check in the wiring test. (See | |
| I/O BD and Drive BD. |
| |
|
|
| |
| Air Damper adjustment fault. | Air Damper adjustment. (See the end of this Section) | |
|
|
| |
Left/right movements of the | Deviation of Roll Volume. | Adjust Volume values in the Test mode. (See | |
Ride is weak and irregular. |
|
| |
Preset pressure is incorrect. | Make pressure adjustment. (See | ||
| |||
|
|
| |
| Air leakage. | Check the Air Drive System. | |
|
|
| |
| Communication fault between I/O | Check in the wiring test. (See | |
| BD and Drive BD. |
| |
|
|
| |
| Malfanctioning of Inclination | Replace the Inclination Sensor. (See | |
| Sensor. |
| |
|
|
| |
Communication play not | Communication cable connection is | Connect the communication cables correctly. (See | |
possible. | incorrect. |
| |
|
|
| |
| Communication settings are wrong. | Correct the settings. (See | |
|
|
| |
Fluorescent lamp doesn't | Connector connection fault. | Check connector connections between the Billboard and | |
light up. |
| PTV. (See Section 6) | |
|
|
| |
| Fluorescent lamp need replacement. | Replace the fluorescent lamp. (See Section 15) | |
|
|
|
CIRCUIT PROTECTOR
CIRCUIT PROTECTOR
Functions due to the activation of bimetal. To restore the function, wait for approximately one minute or longer until the bimetal cools off. (Press the Button.)