10 - 5 AIR CLEANER

The Compressor for this machine is the oilless type and so oil replenishment is not necessary. However, if the Air Cleaner for protecting the Compressor becomes dirty, the Compressor's operation efficiency will decrease, and this may cause malfunctioning. Two spare Air Cleaners are available. Check the Air Cleaners every 2 months.

1Turn the main switch of the AC Unit off.

2 Take out the 4 truss screws and remove the Air Vent on the right side of the Rear Cabinet.

TRUSS SCREW (4)

M4 X 8,BLACK

PHOTO 10. 5 a

AIR VENT

3Removing the Air Vent, the Compressor's Cleaner Cover is appeared. Taking out the fixed screws, remove the Cleaner Cover.

CLEANER COVER

PHOTO 10. 5 b

4Check the Air Cleaner inside the Compressor. If dirty, replace the Air Cleaner.

PHOTO 10. 5 c

www.seuservice.com62

Page 71
Image 71
Sega WaveRunner owner manual 10 5 AIR Cleaner