DISTANCE BETWEEN MACHINES

70cm

Be sure to secure space in excess of 70cm between machines.

FIG. 20. 1

20 - 2 CONNECTING THE COMMUNICATION CABLE

To enable the game machines to serve in a communication play, you must interconnect their game boards with the communication cables (optical fiber cables).

For this wiring, prepare the parts described in Table 5c of Section 5 and a short Phillips screwdriver for M4 screws.

1Turn off power and disconnect the plug. Disconnect the power cord so as not to damage it.

2Referring to Section 7, uncouple and align the machines keeping the workspace in front of the Front Cabinet.

3Remove the Service Lid on the upper front part of the Front Cabinet (see 18-1).

4Take out the 2 truss screws and remove the Lower Lid in front of the Front Cabinet.

TRUSS SCREW (4),black

M4 X 16

5 Take out the 4 truss screws and remove the Side Lid on the side of the Front Cabinet. In this instance, remove the Side Lid that lets the communication cable pass. Depending on the number and arrangement of the interconnected game machines, you may remove either or both of the two Side Lids.

SIDE LID

PHOTO 20. 2 a

www.seuservice.com110

Page 119
Image 119
Sega WaveRunner owner manual Distance Between Machines, 20 2 Connecting the Communication Cable