![](/images/new-backgrounds/1270952/270952135x1.webp)
10 - 2 DEWATERING FROM THE AIR FILTER
Remove the Rear Lid of the Mechanism Base to have the water tank appear in the inner portion on the
DEWATERING PROCEDURE
1Turn the main switch of the AC Unit off.
2Take out the 5 screws to remove
the Rear Lid of the Mechanism Base (FIG. 10. 2 a).
TRUSS SCREW (5)
M4 X 12, black
FIG. 10. 2 a
3The Drain Tube from the Filter is connected to the water tank. Remove the Water Tank from the Mechanism Base by firmly holding the Drain Tube so as not to allow the tube to come off from the water tank.
4 When turning and loosening the drain nozzle underneath the filter in the horizontal direction, water will gush out together with the compressed air. Be sure to firmly hold the Drain Tube so as not to allow the water can splash out in the periphery
(FIG. 10. 2 b).
Press the Drain Nozzle.
FILTER DRAIN TUBE WATER TANK
FILTER |
| WATER TANK |
|
|
|
SHUT OPEN | SHUT OPEN |
| |
Drain Nozzle. |
| WATER TANK | FIG. 10. 2 b |
|
|
| |
|
|
| Firmly hold the Tube. |
5The drained water can be discharged into a sewer system.
6After dewatering is finished, tighten the drain nozzle. Shake the end of the Drain Tube off to remove water thoroughly, put the tube end into the water tank, and return the water tank to the Mechanism Base.
59www.seuservice.com