4 Communications

Issue 10/06

4 Communications

4.1Establishing communications

MICROMASTER 440 STARTER

The following optional components are additionally required in order to establish communications between STARTER and MICROMASTER 440:

¾PC <-> frequency inverter connecting set

¾BOP if the USS standard values (refer to Section 6.4.1 "Serial Interface (USS)") are changed in the MICROMASTER 440 frequency inverter

PC <-> frequency inverter connecting set

MICROMASTER 440

 

USS settings, refer to 6.4.1 "Serial

 

Interface (USS)"

 

 

 

STARTER

 

Menu, Options --> Set PG/PC interface

 

--> Select "PC COM-Port (USS)" -->

 

Properties --> Interface "COM1", select

 

a baud rate

 

 

 

NOTE

 

The USS parameter settings in the

 

MICROMASTER 440 frequency inverter

 

and the settings in STARTER must

 

match!

 

 

4.2Establishing communications MICROMASTER 440 AOP

¾Communications between AOP and MM440 are based on the USS protocol, analog to STARTER and MM440.

¾Contrary to the BOP, the appropriate communication parameters - both for the MM440 as well as for AOP - should be set if the automatic interface detection was not carried-out (refer to Table 4-1).

¾Using the optional components, the AOP can be connected to the communication interfaces (refer to Table 4-1).

Table 4-1

 

 

 

AOP at the BOP link

AOP at the COM link

MM440 parameters

 

 

- baud rate

P2010[1]

P2010[0]

- bus address

P2011

AOP parameters

 

 

- baud rate

P8553

P8553

- bus address

P8552

Options

 

 

- direct connection

No option necessary

Not possible

- indirect connection

BOP/AOP door mounting kit

AOP door mounting kit

 

(6SE6400-0PM00-0AA0)

(6SE6400-0MD00-0AA0)

24

MICROMASTER 440

Operating Instructions (Compact)

Page 24
Image 24