Input voltage range

 

 

 

3 AC 500 V – 600 V, ± 10 %

 

(Unfiltered)

Order No.

6SE6440-

2UE17-

 

2UE21-

2UE22-

2UE24-

2UE25-

2UE27-

2UE31-

2UE31-

 

 

 

5CA1

 

5CA1

 

2CA1

 

0CA1

5CA1

5CA1

1CA1

5DA1

Frame Size

 

 

 

 

 

 

 

 

C

 

 

 

D

Output Rating(CT)

 

[kW]

0,75

 

1,5

 

2,2

 

4,0

5,5

7,5

11,0

15,0

 

[hp]

1,0

 

2,0

 

3,0

 

5,0

7,5

10,0

15,0

20,0

 

 

 

 

 

Output Power

 

[kVA]

1,3

 

2,6

 

3,7

 

5,8

8,6

10,5

16,2

21,0

CT-Input Current 1)

 

[A]

2,0

 

3,7

 

5,3

 

8,1

11,1

14,4

21,5

24,9

CT-Output Current

 

[A]

1,4

 

2,7

 

3,9

 

6,1

9,0

11,0

17,0

22,0

VT-Input Current 1)

 

[A]

3,2

 

4,4

 

6,9

 

9,4

12,6

18,1

24,9

30,0

VT-Output Current

 

[A]

2,7

 

3,9

 

6,1

 

9,0

11,0

17,0

22,0

27,0

Fuse

 

[A]

10

 

10

 

10

 

16

16

25

32

35

Recommended

 

3NA

3803-6

 

3803-6

 

3803-6

 

3805-6

3805-6

3810-6

3812-6

3814-6

For UL specified

 

3NE

*

 

*

 

*

 

*

*

*

*

1803-0

Input Cable, min.

 

[mm2]

1,0

 

1,0

 

1,0

 

1,5

1,5

2,5

4,0

6,0

 

[AWG]

18

 

18

 

18

 

16

16

14

12

10

 

 

 

 

 

Input Cable, max.

 

[mm2]

10,0

 

10,0

 

10,0

 

10,0

10,0

10,0

10,0

35,0

 

[AWG]

8

 

8

 

8

 

8

8

8

8

2

 

 

 

 

 

Output Cable, min.

 

[mm2]

1,0

 

1,0

 

1,0

 

1,0

1,0

2,5

4,0

4,0

 

[AWG]

18

 

18

 

18

 

18

18

14

12

12

 

 

 

 

 

Output Cable, max.

 

[mm2]

10,0

 

10,0

 

10,0

 

10,0

10,0

10,0

10,0

35,0

 

[AWG]

8

 

8

 

8

 

8

8

8

8

2

 

 

 

 

 

Weight

 

[kg]

5,5

 

5,5

 

5,5

 

5,5

5,5

5,5

5,5

16,0

 

[lbs]

12,1

 

12,1

 

12,1

 

12,1

12,1

12,1

12,1

35,0

 

 

 

 

 

Tightening torques for

 

[Nm]

 

 

 

 

 

2,25

 

 

 

10

power terminals

 

[lbf.in]

 

 

 

 

 

(20)

 

 

 

(89)

 

 

 

 

 

 

 

 

 

 

 

Order No.

6SE6440-

2UE31-

 

2UE32-

2UE33-

2UE33-

2UE34-

2UE35-

2UE37-

 

 

 

 

8DA1

 

2DA1

 

0EA1

 

7EA1

5FA1

5FA1

5FA1

 

Frame Size

 

 

 

D

 

 

E

 

F

 

 

Output Rating(CT)

 

[kW]

18,5

 

22,0

 

30,0

 

37,0

45,0

55,0

75,0

 

 

[hp]

25,0

 

30,0

 

40,0

 

50,0

60,0

75,0

100,0

 

 

 

 

 

 

 

Output Power

 

[kVA]

25,7

 

30,5

 

39,1

 

49,5

59,1

73,4

94,3

 

CT-Input Current 1)

 

[A]

30,0

 

35,0

 

48,0

 

58,0

69,0

83,0

113,0

 

CT-Output Current

 

[A]

27,0

 

32,0

 

41,0

 

52,0

62,0

77,0

99,0

 

VT-Input Current 1)

 

[A]

35,0

 

48,0

 

58,0

 

69,0

83,0

113,0

138,0

 

VT-Output Current

 

[A]

32,0

 

41,0

 

52,0

 

62,0

77,0

99,0

125,0

 

Fuse

 

[A]

50

 

63

 

80

 

80

125

160

160

 

Recommended

 

3NA

3820-6

 

3822-6

3824-6

 

3824-6

3132-6

3136-6

3136-6

 

For UL specified

 

3NE

1817-0

 

1818-0

1820-0

 

1820-0

1022-0

1224-0

1224-0

 

Input Cable, min.

 

[mm2]

10,0

 

10,0

 

16,0

 

25,0

25,0

50,0

50,0

 

 

[AWG]

8

 

8

 

6

 

3

3

1/0

1/0

 

 

 

 

 

 

 

Input Cable, max.

 

[mm2]

35,0

 

35,0

 

35,0

 

35,0

150,0

150,0

150,0

 

 

[AWG]

2

 

2

 

2

 

2

300

300

300

 

 

 

 

 

 

 

Output Cable, min.

 

[mm2]

6,0

 

10,0

 

16,0

 

16,0

25,0

35,0

50,0

 

 

[AWG]

10

 

8

 

6

 

6

3

2

1/0

 

 

 

 

 

 

 

Output Cable, max.

 

[mm2]

35,0

 

35,0

 

35,0

 

35,0

150,0

150,0

150,0

 

 

[AWG]

2

 

2

 

2

 

2

300

300

300

 

 

 

 

 

 

 

Weight

 

[kg]

16,0

 

16,0

 

20,0

 

20,0

56,0

56,0

56,0

 

 

[lbs]

35,0

 

35,0

 

44,0

 

44,0

123,0

123,0

123,0

 

 

 

 

 

 

 

Tightening torques for

 

[Nm]

 

 

 

10

 

 

 

50

 

 

power terminals

 

[lbf.in]

 

(89)

 

 

 

(445)

 

 

1)Secondary conditions: Input current at the rated operating point - applies for the short-circuit voltage of the line supply Vk = 2 % referred to the rated drive converter power and a rated line supply voltage of 500 V without line commutating reactor.

*UL listed fuses such as Class NON from Bussmann are required for use in America

12