6 Commissioning | Issue 10/06 |
Supplementary torque setpoint
¾In the vector mode – with / without encoder – the speed controller can be subordinate to a constant or variable supplementary torque.
¾The supplementary setpoint can be used to advantage for hoisting gear with low intrinsic friction when starting in the vertical direction. The supplementary torque setpoint must always be impressed in the hoisting (raising) direction (please observe the sign!). As a result of the supplementary torque, also when lowering, a slip is immediately established that has a stabilizing effect on the
¾The sign of the supplementary torque setpoint can be determined as follows in the commissioning phase with the appropriate care and taking into account all of the relevant safety regulations:
Hoist (raise) a minimum load using the hoisting gear and
¾An empirical value of approx. 40 % of the rated motor torque r0333 has lead to good results for existing hoisting gear
(carefully observe the sign!).
P1511=...
CI: Supplementary torque setpoint | 0:0 |
Selects the source of the supplementary torque setpoint.
Frequent settings:
2889 Fixed setpoint 1 as a %
2890 Fixed setpoint 2 as a %
755.0Analog input 1
755.1Analog input 2 2015. 2 USS (BOP link)
2018. 2 USS (COM link)
2050. 2 CB (e.g. PROFIBUS)
|
|
|
| Droop |
|
|
|
| Pre- |
|
| r1518 |
|
|
| control |
|
|
| |
|
|
|
|
|
| |
|
|
| Kp | Tn |
|
|
r1170 | – | *) | PI | r1538 | r1538 |
|
|
| |||||
Freq. setpoint |
|
| Speed |
|
| |
| – | controller |
| Torque | ||
|
| Ti |
|
|
| |
r0063 |
|
| r1539 | r1539 | setpoint | |
|
|
| ||||
|
|
|
| |||
|
|
|
| r1508 |
| r0079 |
Act. frequency |
|
|
|
| r1515 |
|
|
|
|
|
|
|
CI: Add. trq. setp
P1511.C
(0:0)
|
| Ti | Kp | Tn |
*) only active, if | SLVC: | P1452 | P1470 | P1472 |
(P1496 > 0) | VC: | P1442 | P1460 | P1462 |
54 | MICROMASTER 440 |
Operating Instructions (Compact) |