6 Commissioning | Issue 10/06 |
6.4.18.4DC brake
P1230 = ...
P1232 =...
P1233 =...
BI: Enabling the DC brake
This enables DC braking using a signal that was used from an external source. The function remains active as long as the external input signal is active. DC braking causes the motor to quickly stop by injecting a DC current
BI: Enable DC brk.
P1230.C | 1 |
| |
(0:0) | 0 |
| |
⏐f⏐ | t | ||
f_set | |||
| f* | ||
| DC braking | ||
|
| ||
|
| f_act | |
|
| t | |
| i | P0347 | |
|
| t |
DC braking active
r0053 | 1 |
|
|
|
|
|
|
|
|
|
|
|
| ||
Bit00 | 0 |
|
|
|
|
|
|
|
|
|
| t | |||
|
|
|
|
|
| ||
Note: DC brake can be applied in drive states r0002 = 1, 4, 5 |
|
| |||||
|
|
|
|
|
|
| |
DC braking current (entered in %) |
| 100 % | |||||
|
|
| |||||
Defines level of DC current in [%] relative to rated motor current (P0305). |
|
| |||||
|
|
| |||||
Duration of DC braking (entered in s) |
| 0 s |
Defines duration for which DC injection braking is to be active following an OFF1 or OFF3 command.
1 |
| |
ON |
| |
OFF1/OFF3 | t | |
| P0347 | |
OFF2 |
| |
| t | |
⏐f⏐ |
| |
P1234 | OFF2 | |
DC braking | ||
| ||
| t |
DC braking active
r0053 | 1 |
|
Bit00 | 0 | t |
|
| P1233 |
58 | MICROMASTER 440 |