2 Electrical Installation

Issue 10/06

Input voltage range

 

 

 

 

3 AC 200 V – 240 V. ± 10 %

 

 

 

 

 

 

 

 

 

(Unfiltered)

Order No.

6SE6440-

 

2UC11

 

2UC12

 

2UC13

 

2UC15

 

2UC17

 

2UC21

 

2UC21

 

2UC22

 

2UC23

 

 

 

 

-2AA1

 

-5AA1

 

-7AA1

 

-5AA1

 

-5AA1

 

-1BA1

 

-5BA1

 

-2BA1

 

-0CA1

Frame Size

 

 

 

 

 

 

A

 

 

 

 

 

 

 

 

B

 

 

 

 

 

 

 

 

 

 

 

C

 

Output Rating(CT)

 

[kW]

0,12

 

 

0,25

 

 

0,37

 

 

0,55

 

 

0,75

 

 

1,1

 

 

1,5

 

2,2

 

3,0

 

[hp]

0,16

 

 

0,33

 

 

0,5

 

 

0,75

 

 

1,0

 

 

 

1,5

 

 

2,0

 

3,0

 

4,0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Output Power

 

[kVA]

0,4

 

 

0,7

 

 

1,0

 

 

1,3

 

 

1,7

 

 

 

2,4

 

 

3,2

 

4,6

 

6,0

CT-Input Current 1)

 

[A]

1,1

 

 

1,9

 

 

2,7

 

 

3,6

 

 

4,7

 

 

 

6,4

 

 

8,3

 

11,7

 

15,6

CT-Output Current

 

[A]

0,9

 

 

1,7

 

 

2,3

 

 

3,0

 

 

3,9

 

 

 

5,5

 

 

7,4

 

10,4

 

13,6

Fuse

 

[A]

10

 

 

10

 

 

10

 

 

16

 

 

 

16

 

 

 

20

 

 

20

 

25

 

25

Recommended

 

3NA

3803

 

 

3803

 

 

3803

 

3805

 

 

3805

 

3807

 

 

3807

 

3810

 

3810

For UL specified

 

 

*

 

 

*

 

 

*

 

 

*

 

 

 

*

 

 

 

*

 

 

*

 

*

 

*

Input Cable, min.

 

[mm2]

1,0

 

 

1,0

 

 

1,0

 

 

1,5

 

 

1,5

 

 

 

2,5

 

 

2,5

 

2,5

 

4,0

 

[AWG]

18

 

 

18

 

 

18

 

 

16

 

 

 

16

 

 

 

14

 

 

14

 

14

 

12

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Input Cable, max.

 

[mm2]

2,5

 

 

2,5

 

 

2,5

 

 

2,5

 

 

2,5

 

 

 

6,0

 

 

6,0

 

6,0

 

10,0

 

[AWG]

14

 

 

14

 

 

14

 

 

14

 

 

 

14

 

 

 

10

 

 

10

 

10

 

8

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Output Cable, min.

 

[mm2]

1,0

 

 

1,0

 

 

1,0

 

 

1,0

 

 

1,0

 

 

 

1,0

 

 

1,0

 

1,0

 

1,5

 

[AWG]

18

 

 

18

 

 

18

 

 

18

 

 

 

18

 

 

 

18

 

 

18

 

18

 

16

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Output Cable, max.

 

[mm2]

2,5

 

 

2,5

 

 

2,5

 

 

2,5

 

 

2,5

 

 

 

6,0

 

 

6,0

 

6,0

 

10,0

 

[AWG]

14

 

 

14

 

 

14

 

 

14

 

 

 

14

 

 

 

10

 

 

10

 

10

 

8

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Weight

 

[kg]

1,3

 

 

1,3

 

 

1,3

 

 

1,3

 

 

1,3

 

 

 

3,3

 

 

3,3

 

3,3

 

5,5

 

[lbs]

2,9

 

 

2,9

 

 

2,9

 

 

2,9

 

 

2,9

 

 

 

7,3

 

 

7,3

 

7,3

 

12,1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Tightening torques

 

[Nm]

 

 

 

 

1,1

 

 

 

 

 

 

 

 

1,5

 

 

 

 

 

 

 

 

 

 

2,25

 

 

for power terminals

 

[lbf.in]

 

 

 

 

(10)

 

 

 

 

 

 

 

 

(13,3)

 

 

 

 

 

 

 

 

 

(20)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Order No.

6SE6440-

 

2UC24-

2UC25-

2UC27-

2UC31-

2UC31-

2UC31-

2UC32-

2UC33-

2UC33-

2UC34-

 

 

 

 

0CA1

 

5CA1

 

5DA1

 

1DA1

 

5DA1

 

8EA1

 

2EA1

 

0FA1

 

7FA1

5FA1

Frame Size

 

 

 

C

 

 

 

 

 

 

D

 

 

 

 

 

 

 

E

 

 

 

 

 

F

 

Output Rating(CT)

 

[kW]

 

4,0

 

 

5,5

 

7,5

 

11,0

 

 

15,0

 

18,5

 

22,0

 

 

30,0

 

 

37,0

 

45,0

 

[hp]

 

5,0

 

 

7,5

 

10,0

 

15,0

 

 

20,0

 

25,0

 

30,0

 

 

40,0

 

 

50,0

 

60,0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Output Power

 

[kVA]

 

7,7

 

 

9,6

 

12,3

 

18,4

 

 

23,7

 

29,8

 

35,1

 

 

45,6

 

 

57,0

 

67,5

CT-Input Current 1)

 

[A]

 

19,7

 

 

26,5

 

34,2

 

38,0

 

 

50,0

 

62,0

 

71,0

 

 

96,0

 

 

114,0

 

135,0

CT-Output Current

 

[A]

 

17,5

 

 

22,0

 

28,0

 

42,0

 

 

54,0

 

68,0

 

80,0

 

 

104,0

 

130,0

 

154,0

VT-Input Current 1)

 

[A]

 

28,3

 

 

34,2

 

38,0

 

50,0

 

 

62,0

 

71,0

 

96,0

 

 

114,0

 

135,0

 

164,0

VT-Output Current

 

[A]

 

22,0

 

 

28,0

 

42,0

 

54,0

 

 

68,0

 

80,0

 

104,0

 

130,0

 

154,0

 

-

Fuse

 

[A]

 

32

 

 

35

 

50

 

80

 

 

80

 

100

 

125

 

 

200

 

 

200

 

250

Recommended

 

3NA

 

3812

 

 

3814

 

3820

 

3824

 

3824

 

3830

 

3832

 

 

3140

 

3142

 

3144

For UL specified

 

3NE

 

*

 

 

*

 

1817-0

1820-0

1820-0

1021-0

1022-0

1225-0

1225-0

1227-0

Input Cable, min.

 

[mm2]

 

4,0

 

 

4,0

 

10,0

 

16,0

 

 

16,0

 

25,0

 

25,0

 

 

70,0

 

 

70,0

 

95,0

 

[AWG]

 

12

 

 

12

 

8

 

6

 

 

6

 

3

 

 

3

 

 

 

2/0

 

 

2/0

 

3/0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Input Cable, max.

 

[mm2]

 

10,0

 

 

10,0

 

35,0

 

35,0

 

 

35,0

 

35,0

 

35,0

 

 

150,0

 

150,0

 

150,0

 

[AWG]

 

8

 

 

8

 

2

 

2

 

 

2

 

2

 

 

2

 

 

 

300

 

 

300

 

300

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Output Cable, min.

 

[mm2]

 

4,0

 

 

4,0

 

10,0

 

16,0

 

 

16,0

 

25,0

 

25,0

 

 

50,0

 

 

70,0

 

95,0

 

[AWG]

 

12

 

 

12

 

8

 

6

 

 

6

 

3

 

 

3

 

 

 

1/0

 

 

2/0

 

3/0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Output Cable, max

 

[mm2]

 

10,0

 

 

10,0

 

35,0

 

35,0

 

 

35,0

 

35,0

 

35,0

 

 

150,0

 

150,0

 

150,0

 

[AWG]

 

8

 

 

8

 

2

 

2

 

 

2

 

2

 

 

2

 

 

 

300

 

 

300

 

300

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Weight

 

[kg]

 

5,5

 

 

5,5

 

17,0

 

16,0

 

 

16,0

 

20,0

 

20,0

 

 

55,0

 

 

55,0

 

55,0

 

[lbs]

 

12,1

 

 

12,1

 

37,0

 

35,0

 

 

35,0

 

44,0

 

44,0

 

 

121,0

 

121,0

 

121,0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Tightening torques

 

[Nm]

 

2,25

 

 

 

 

 

 

 

 

10

 

 

 

 

 

 

 

 

 

 

 

50

 

 

for power terminals

 

[lbf.in]

 

(20)

 

 

 

 

 

 

 

 

(89)

 

 

 

 

 

 

 

 

 

 

 

(445)

 

 

1)Secondary conditions: Input current at the rated operating point - applies for the short-circuit voltage of the line supply Vk = 2 % referred to the rated drive converter power and a rated line supply voltage of 240 V without line commutating reactor.

*UL listed fuses such as Class NON from Bussmann are required for use in America

8

MICROMASTER 440

Operating Instructions (Compact)

Page 8
Image 8
Siemens 440 1BA1 5BA1, CT-Output Current, For UL specified Input Cable, min, Input Cable, max, Output Cable, max, 2UC31