Date
Real-Time Clock
Set Time
Difference Time
Parameter Changeover Optional
Synchronizing the Clock
Configuring Each Parameter in Each Set
Configuring a Parameter Set
Accesses this parameter set
PARAM.C/O
Copying Parameter Sets
Selecting the Active Parameter Set
Address Copy Action
Power System Settings
System Settings
Deactivating Parameter Changeover
Settings for Measured Value Monitoring
Fuse Fail
Distance Protection Settings
Addr. Block
Fault Loop Earthed Network Fault Loop NON-EARTHED NET
Z1B Z1L
General Settings
Independent Zones Z1, Z2, Z3
Controlled Overreach Zones Z1B and Z1L
Zone & Description Preset
Prerequisite Settings Addr. LCD Text
Overcurrent Fault Detection Settings
Zone & Description
Exist U/I
Voltage Controlled Overcurrent Fault Detection
PROG. U/I
Exist Impedance Zone
Polygonal Impedance Fault Detection
PROG. ZA
RA1 RA2 RAE
Preset Options/Range
Determination of the Fault Loop for Grounded Systems
LCD Text Description
Phase Pref
Power Swing Protection 2000 Optional
L3L1 Acyclic
Exist Impedance Zone Exist
Permissive Underreach Transfer
Addr LCD Text Description Preset
Permissive Overreach Transfer
Putt Mode SEND-PRL REC-PROL SEND-DEL
Z1B Acceleration
OFF FD Acceleration
SEND-DEL Echo ECHO-DEL ECHO-IMP ECHO-BLO
Pott Mode Transblo Wait TB SEND-PRL
Z1B Release
Forwards
Stage
MAN. Close
Exist Compensated Isolated
Earthfault
CT ERR CT ERR. F1 CT ERR. F2
Directional D.T. Solidly Earthed
Directional Protection With Nondirectional Backup
Direction NON-DIR
Direct
Block
DIREC. Comparison Solidly Earthed
Nondirectional, Inverse Time Overcurrent Protection
Description Preset
Charac
Normal Inverse
Option
Device Configuration for Automatic Reclose
Internal AR
Addr LCD Text Description Preset Options/Range
Automatic Reclose Function Settings
Terminology
Prerequisite Setting Addr LCD Text Description
Fault Location Settings
Function
Turning the Relay Functions On and Off
See Section
Compar Echo
Procedure for Configuring the Logical Functions
Configuration Settings
BelowFAILU. RELAY424V
Addr Unit Index No
Presettings
LCD Text 2nd line
AR on no AR OFF no
LED
Binary Inputs
LED Indicators
Signal Relays
Trip Relays
This page intentionally blank
Displaying System and Relay Information
This page intentionally blank
Using the Operator Panel to Display Information
Event Log
Ess. ANNUNCIATIONS5000
Event Log Messages
Storage and Display Description
LCD Text 2nd line Description Possible Tag
Binary Inputs
Monitoring Functions
General
Ground Fault Protection
Power Swing Function
Automatic Reclose Function
Circuit Breaker Test Function
Target Log for All Systems 5200, 5300,
Table Status
7SA511 Line Protection Re ay Chapter
Example Sys em Fault Messages
Command. DisTrip46 23C
LCD Text 2nd line Description
Target Log Messages
Distance Protection
High-Resistance Ground Fault Protection in Grounded Systems
Fault Location
Emergency Overcurrent Protection
Automatic Reclose
Began. E/FDetection002104357 C
Circuit Breaker Operation Statistics
Isolated Ground Fault Data Log Messages