DART 200 CDPD Modem User’s Guide | 8 Application Programming |
∙Manual registration
∙Automatic registration at
∙Automatic registration whenever the modem is not registered
∙Automatic registration when connection originates
These options are described in detail after Registration Timer.
Registration timer
Manual registration
This option allows either the user or the MAS to control exactly when the registration will occur. It is implemented by the AT/R1 command. After issuing an AT\R1 command, the AT command processor is blocked and the modem does not respond to any AT commands, until the registration completes successfully or the timer expires.
Since waiting to try another command can be very frustrating, large timer values (above 60 seconds) are not recommended. Limit manual registration by AT\R1 to testing situations, and then with the timer value set in the 20 to 30 second range.
After executing these commands, the settings should be saved by an AT&W command. This feature can be deactivated by the AT\R5 command. The AT command processor is not blocked when this type of registration is in process.
This function is not the complete answer to automatic registration since the timer might expire before registration is successful. Also, in instances where registration is lost due to loss of radio signal, such as in a mobile application, the register at
|