DART 200 CDPD Modem User’s Guide | 2 Installation and Setup |
?
NOTE:
Most carriers and equipment manufacturers follow these guidelines making problem determination easier. If these guidelines are not followed, more ingenuity is required.
The bit definitions in Figure
∙Channel acquired indicator (bit 7)
∙Automatic registration switch (bit 5)
∙Registration indicator (bit 0)
An odd value in
If the DART has problems registering, begin problem determination by checking the contents of
∙
Return codes 0 through 7 are suggested by the CDPD specification.
0Reset condition - Also, registration is incomplete but did not time out. Refer to the description of
1Registration denied - Usually means IP Address is being used by another device. On some systems it could also be an invalid NEI or a credentials mismatch
2Service currently unavailable
3Invalid NEI (IP Address)
4Insufficient authentication credentials
5Unsupported authentication credentials
6NEI has exceeded usage limitations
7Service denied on this subnetwork - service can be obtained on an alternate Service Provider network
250Timer expired waiting for the home MDIS Intermediate System Confirmation (ISC) registration response - Usually caused by router problems between the home and serving MDISs
251MDLP parameters unsupported
252MDLP version unsupported
254Could not access the CDPD network
255Could not
∙
CDPD registration is a
0Protocol not active
1Waiting for Temporary Equipment Identifier (TEI) assignment from MDIS
2Link connection establishment pending - waiting for the Unnumbered Acknowledgement (UA) from MDIS
3Encryption key exchange pending - waiting for MDIS Key Exchange (IKE) from MDIS
4Registration pending - End System Hello (ESH) sent, waiting for Intermediate System Confirmation (ISC) from MDIS
Sierra Wireless, Inc. |