8.Check your system documentation for any additional actions that may be required to configure the system software for the newly inserted card.

For example, in some systems you must type the following command:

%cfgadm -c configure attachment_point

This turns off the blue LED and initiates the software, which responds by configuring the system software for the newly inserted card.

If the blue LED does not go off, you know that the card is not properly seated and you must remove it and repeat the installation procedure.

If the blue LED does go off, proceed to Step 9.

9.Using a No. 0 Phillips screwdriver, tighten the captive screws inside the card’s ejection lever.

FIGURE 3-3Tightening the Ejection Lever Captive Screw

10.Remove the wrist strap from the chassis and your wrist.

11.Connect one end of the multimode fiber cable to the fiber receptacle on the SunATM adapter and the other end to the ATM networking device (for example, an ATM switch).

Refer to the documentation supplied with the ATM networking device for additional cabling information.