AMEasure Subsystem (Audio Analyzer)
AM700 Audio Measurement Set Programmer Manual 3–17
AMEasure:SETTled:IMD:TOLerance <numeric_value>
Usage: Sets or queries the settling tolerance setting of the intermodulation distortion
measurement for the designated AME.
Range: 0 to 100%
Query: AME:SETT:IMD:TOL? returns the global setting for IMD tolerance for
settled data points.
*RST: 0.100%
AMEasure:SETTled:LDIFference:RESolution <numeric_value>
Usage: Sets or queries the settling resolution setting of the level difference measure-
ment for the designated AME.
Range: 0 to 200 dB
Query: AME:SETT:LDIF:RES? returns the settling resolution setting of the level
difference.
*RST: 0.10 dB
AMEasure:SETTled:LDIFference:TOLerance <numeric_value>
Usage: Sets or queries the settling tolerance setting of the level difference measurement
for the designated AME.
Range: 0 to 100%
Query: AME[:SETT:LDIF:TOL? returns the global tolerance setting for level
difference to be considered settled data.
*RST: 1.000%