Texas Instruments TMS320DM643X DMP manual Mdio Control Register Control

Models: TMS320DM643X DMP

1 120
Download 120 pages 29.22 Kb
Page 56
Image 56

www.ti.com

MDIO Registers

4.2MDIO Control Register (CONTROL)

The MDIO control register (CONTROL) is shown in Figure 14 and described in Table 12.

Figure 14. MDIO Control Register (CONTROL)

31

30

29

28

24

23

21

20

19

18

17

16

IDLE

ENABLE

Rsvd

HIGHEST_USER_CHANNEL

Reserved

 

PREAMBLE

FAULT

FAULTENB

Reserved

R-1

R/W-0

R-0

 

R-1

R-0

 

R/W-0

R/WC-0

R/W-0

 

R-0

15

 

 

 

 

 

 

 

 

 

 

0

 

 

 

 

 

CLKDIV

 

 

 

 

 

 

 

 

 

 

 

R/W-FFh

 

 

 

 

 

 

LEGEND: R/W = R = Read only; R/W = Read/Write; WC = Write 1 to clear; -n= value after reset

 

 

 

 

Table 12. MDIO Control Register (CONTROL) Field Descriptions

Bit

Field

Value

Description

31

IDLE

 

State machine IDLE status bit.

 

 

0

State machine is not in idle state.

 

 

1

State machine is in idle state.

30

ENABLE

 

State machine enable control bit. If the MDIO state machine is active at the time it is

 

 

 

disabled, it will complete the current operation before halting and setting the idle bit.

 

 

0

Disables the MDIO state machine.

 

 

1

Enable the MDIO state machine.

29

Reserved

0

Reserved

28-24

HIGHEST_USER_CHANNEL

0-1Fh

Highest user channel that is available in the module. It is currently set to 1. This

 

 

 

implies that MDIOUserAccess1 is the highest available user access channel.

23-21

Reserved

0

Reserved

20

PREAMBLE

 

Preamble disable

 

 

0

Standard MDIO preamble is used.

 

 

1

Disables this device from sending MDIO frame preambles.

19

FAULT

 

Fault indicator. This bit is set to 1 if the MDIO pins fail to read back what the device

 

 

 

is driving onto them. This indicates a physical layer fault and the module state

 

 

 

machine is reset. Writing a 1 to it clears this bit.

 

 

0

No failure

 

 

1

Physical layer fault; the MDIO state machine is reset.

18

FAULTENB

 

Fault detect enable. This bit has to be set to 1 to enable the physical layer fault

 

 

 

detection.

 

 

0

Disables the physical layer fault detection.

 

 

1

Enables the physical layer fault detection.

17-16

Reserved

0

Reserved

15-0

CLKDIV

0-FFFFh

Clock Divider bits. This field specifies the division ratio between the peripheral clock

 

 

 

and the frequency of MDCLK. MDCLK is disabled when CLKDIV is cleared to 0.

 

 

 

MDCLK frequency = peripheral clock frequency/(CLKDIV + 1).

56 Ethernet Media Access Controller (EMAC)/SPRU941A –April 2007

Management Data Input/Output (MDIO)

Submit Documentation Feedback

 

Page 56
Image 56
Texas Instruments TMS320DM643X DMP manual Mdio Control Register Control Field Descriptions