www.ti.com

Ethernet Media Access Controller (EMAC) Registers

5.4Receive Identification and Version Register (RXIDVER)

The receive identification and version register (RXIDVER) is shown in Figure 30 and described in Table 29.

Figure 30. Receive Identification and Version Register (RXIDVER)

31

 

 

16

 

RXIDENT

 

 

 

R-0Ch

 

15

8

7

0

 

RXMAJORVER

 

RXMINORVER

 

R-0Ah

 

R-07h

LEGEND: R = Read only; -n= value after reset

Table 29. Receive Identification and Version Register (RXIDVER) Field Descriptions

Bit

Field

Value

Description

31-16

RXIDENT

 

Receive identification value.

 

 

Ch

Current receive identification value.

15-8

RXMAJORVER

 

Receive major version value. Revisions are indicated by a revision code taking the format

 

 

 

RXMAJORVER.RXMINORVER.

 

 

Ah

Current receive major version value.

7-0

RXMINORVER

 

Receive minor version value. Revisions are indicated by a revision code taking the format

 

 

 

RXMAJORVER.RXMINORVER.

 

 

7h

Current receive minor version value.

5.5Receive Control Register (RXCONTROL)

The receive control register (RXCONTROL) is shown in Figure 31 and described in Table 30.

Figure 31. Receive Control Register (RXCONTROL)

31

 

16

Reserved

 

 

R-0

 

 

15

1

0

Reserved

 

RXEN

R-0

 

R/W-0

LEGEND: R = Read only; R/W = Read/Write; -n= value after reset

Table 30. Receive Control Register (RXCONTROL) Field Descriptions

Bit

Field

Value

Description

31-1

Reserved

0

Reserved

0

RXEN

 

Receive enable

 

 

0

Receive is disabled.

 

 

1

Receive is enabled.

SPRU941A –April 2007Ethernet Media Access Controller (EMAC)/ 73

Submit Documentation Feedback

Management Data Input/Output (MDIO)

 

Page 73
Image 73
Texas Instruments TMS320DM643X DMP Receive Identification and Version Register Rxidver, Receive Control Register Rxcontrol