www.ti.com

Ethernet Media Access Controller (EMAC) Registers

5.6Receive Teardown Register (RXTEARDOWN)

The receive teardown register (RXTEARDOWN) is shown in Figure 32 and described in Table 31.

Figure 32. Receive Teardown Register (RXTEARDOWN)

31

 

 

16

 

Reserved

 

 

 

R-0

 

 

15

3

2

0

Reserved

 

 

RXTDNCH

R-0

 

 

R/W-0

LEGEND: R = Read only; R/W = Read/Write; -n= value after reset

Table 31. Receive Teardown Register (RXTEARDOWN) Field Descriptions

Bit

Field

Value

Description

31-3

Reserved

0

Reserved

2-0

RXTDNCH

0-7h

Receive teardown channel. The receive channel teardown is commanded by writing the encoded value

 

 

 

of the receive channel to be torn down. The teardown register is read as 0.

 

 

0

Teardown receive channel 0

 

 

1h

Teardown receive channel 1

 

 

2h

Teardown receive channel 2

 

 

3h

Teardown receive channel 3

 

 

4h

Teardown receive channel 4

 

 

5h

Teardown receive channel 5

 

 

6h

Teardown receive channel 6

 

 

7h

Teardown receive channel 7