Chapter 8 Knob Functions

PITCH

Range: -128to +127

Default: +000

Works on: Sample tracks

Adjusts the pitch of the sample playback. Turn the knob right to increase the pitch, or left to reduce it. Each increment corresponds to 20 cents (where 100 cents is equivalent to 1 semitone).

On LOOP tracks only: If you set the track’s BPM TRACKING to CHNG PITCH , this function is disabled and the SU700 automatically controls the pitch so as to match the tempo. In this case the numerical setting is indicated on the screen as “---” and the meter indication is fixed at the zero level. (Refer to the explanation of the TRACK SET SETUP job on page 236.)

ATTACK

Range:

000 to 127

Default:

Loop: 024

 

C-Loop, Free: 000

Works on:

Sample tracks

Applies a fade-in to the sample. Higher values increase the length of the fade; 000 applies no fade at all.

A fade-inrefers to a gradual rise in the sample level, starting at the note-on event (or pad press). The following illustration shows the concept.

Attack=0 (No fade-in)

Attack>0 (Fade-in)

Level

Level

 

 

 

 

 

 

 

Time

 

Time

Note-On

Note-Off

Note-On

Note-Off