4. Installing the AIEB1 Board

3

2 1

The optional AIEB1 Input/Output expansion board adds digital I/O (both optical and coaxial formats) and six assignable outputs to the SU700.

Preparation

1. The SU700 package includes a short flat cable and a short round 3-wire cable specially designed for use with the AIEB1 board. Be sure that you have these cables on hand. Note that one end of the short flat cable is “banded” (has a bulging ferrite core

near the connector), while the other end has no band.

2. Remove the AIEB1 board from its package, and check that three cables are attached.

The board ships with three attached cables, as illustrated above.

1Long flat cable

2Long round 3-wire cable

3Round 4-wire cable

3.Disconnect the long flat cable and the long round 3-wire cable from the board, and store or discard them. Note the location of the board connectors to which these cables were attached.

These cables are not appropriate for use in the SU700.

4.Connect the non-banded end of the short flat cable (described in Step 1 above) to the now-empty flat-cable connector on the board (connector “CN2”).

Be sure to connect the non-banded end, leaving the banded end free.

Disconnect here.

Attach this end

Ferrite coreof cable to board.

Ferrite core must be on unconnected end.

Connect short flat cable and short 3-wire cable (supplied with the SU700 package) here.