Chapter 10 Jobs

Procedure

Be sure that you have selected the song containing the sample(s) you want to work on.

1. Press SAMPLE DELETE.

The track brackets indicate the currently selected sample track. If the track is empty, the screen displays the NO SAMPLE message. If the track contains a sample, the screen displays the sample name.

2.If necessary, change the track selection by pressing the appropriate bank selector and/or pad.

The SU700 plays out the sample each time you hit the pad. You may want to listen to make sure you have selected the correct sample for deletion.

3.Press [OK].

The screen displays ARE YOU SURE?, giving you one last chance to change your mind. If you do not wish to delete the sample, press [CANCEL] once and return to step 2, or press twice to exit.

4.Press [OK].

The SU700 deletes the sample and returns you to the main screen.

10.3.6RESAMPLE Group

Use these jobs to resample an existing sample or to create a single sample from an entire sequence. When you resample, you record a new sample using the sound of the source track or source sequence as your source.

What The Jobs Do

TRACK

Resamples a single track (the track’s sample as adjusted by

 

knob data).

SEQ

Generates a sample from an entire sequence (song).

RESAMPLE TRACK

Use to: Resample a selected sample.

Explanation

This job records a new sample of an existing sample. The new sample will capture the sound of the source sample as modified by the source track’s current knob settings. In other words, the knob settings are incorporated directly into the new waveform.

272