Configuration 81

Control Panel Parameters

Table 7 • Print Engine Parameters (Page 18 of 25)

 

 

Parameter

 

 

Action/Explanation

 

 

 

 

 

 

 

 

 

 

 

Set Delimiter Character

 

DELIMITER CHAR

 

 

 

 

 

The delimiter character is a two-digit hex value used as a parameter place

 

-

<,>2CH

+

 

marker in ZPL/ZPL II format instructions. See the ZPL II Programming

 

 

 

 

 

Guide for more information.

 

 

 

 

 

Note • Do not use the same hex value for the control, format, and

 

 

 

 

 

delimiter character. The print engine must see different characters

 

 

 

 

 

to work properly.

 

 

 

 

 

Default: 2C (comma)

 

 

 

 

 

Range: 00 to FF

 

 

 

 

 

To change the value shown:

 

 

 

 

 

1. Press the left oval to move to the next digit position.

 

 

 

 

 

2. Press the right oval to increase the value of the digit.

 

 

 

 

 

 

 

 

 

 

 

Select ZPL Mode

 

ZPL MODE

 

 

 

 

 

The print engine remains in the selected mode until it is changed by this

 

-

ZPL II

+

 

parameter or by using a ZPL/ZPL II command. The print engine accepts

 

 

 

 

 

label formats written in either ZPL or ZPL II, eliminating the need to

 

 

 

 

 

rewrite any ZPL formats that already exist. See the ZPL II Programming

 

 

 

 

 

Guide for more information on the differences between ZPL and ZPL II.

 

 

 

 

 

Default: ZPL II

 

 

 

 

 

Selections: ZPL II, ZPL

 

 

 

 

 

To change the value shown:

 

 

 

 

 

1. Press the left or right oval to toggle between the options.

 

 

 

 

 

 

 

 

 

 

 

Select Media Power-Up Option

 

MEDIA POWER UP

 

 

 

 

 

This parameter sets the action of the media when you turn on the

 

- CALIBRATION+

 

 

print engine.

 

 

 

 

 

Default: CALIBRATION

 

 

 

 

 

Selections: FEED, CALIBRATION, LENGTH, SHORT CAL, and NO

 

 

 

 

 

MOTION

 

 

 

 

 

Feed—feeds the labels to the first registration point.

 

 

 

 

 

Calibration—determines the length of the label and adjusts the

 

 

 

 

 

sensor settings.

 

 

 

 

 

Length—In continuous mode, feeds the last stored label length. In

 

 

 

 

 

noncontinuous mode, calibrates based on the maximum label length

 

 

 

 

 

setting (see Set Maximum Label Length on page 68).

 

 

 

 

 

Short Cal—calibrates label length using the current sensor settings.

 

 

 

 

 

No Motion—the media does not move. You must press FEED to

 

 

 

 

 

cause the print engine to resynch to the start of the next label.

 

 

 

 

 

To change the value shown:

 

 

 

 

 

1. Press the left or right oval to scroll through the options.

 

 

 

 

 

 

6/29/11

110PAX4/R110PAX4 User Guide

57512L-004 Rev. A