86Configuration

Control Panel Parameters

Table 7 • Print Engine Parameters (Page 23 of 25)

 

 

Parameter

 

 

Action/Explanation

 

 

 

 

 

 

 

 

 

 

 

Set Ribbon Low Mode

 

RIBBON LOW MODE

 

 

 

 

 

When the Ribbon Low feature is off, the output signal (Pin 9) does not

 

-

25M

+

 

function, the LOW RIBBON warning is not displayed, and the print engine

 

 

 

 

 

continues to print until it runs out of ribbon.

 

 

 

 

 

When the Ribbon Low feature is set to any of the lengths, output signal

 

 

 

 

 

(Pin 9) on the applicator port is functional. When the amount of ribbon on

 

 

 

 

 

the supply spindle reaches the specific length, the output signal asserts to

 

 

 

 

 

provide a RIBBON LOW warning. For print engines with the RIBBON

 

 

 

 

 

LOW OUTPUT parameter, set the output signal to assert HIGH or LOW.

 

 

 

 

 

For print engines without this parameter, the signal asserts HIGH.

 

 

 

 

 

Default: 25M

 

 

 

 

 

Selections: OFF, 25M, 50M, 75M, 100M

 

 

 

 

 

To change the value shown:

 

 

 

 

 

1. Press the left or right oval to scroll through the options.

 

 

 

 

 

 

 

 

 

 

 

Set Ribbon Low Output

 

RIB LOW OUTPUT

 

 

 

 

 

Note • This parameter is not available on older 110PAX4 firmware

 

-

ACTIVE HIGH

+

 

and will be added to a future release of the R110PAX4. Check for

 

 

 

 

 

the latest firmware at http://www.zebra.com/firmware.

 

 

 

 

 

When the Ribbon Low feature is on, this parameter determines if the output

 

 

 

 

 

signal on Pin 9 is HIGH or LOW.

 

 

 

 

 

Default: ACTIVE HIGH

 

 

 

 

 

Selections: ACTIVE HIGH, ACTIVE LOW

 

 

 

 

 

 

 

 

 

 

 

Set Reprint Mode

 

REPRINT MODE

 

 

 

+

 

When the Reprint feature is enabled, the reprint input signal (Pin 6) on the

 

-

DISABLED

 

applicator port is functional. When the input signal is asserted, the last label

 

 

 

 

 

printed is printed again. (This includes non-printing labels.) When the

 

 

 

 

 

Reprint feature is disabled, the reprint input signal is ignored.

 

 

 

 

 

Note • The ^SP ZPL command is ignored when the Reprint feature

 

 

 

 

 

is enabled. When the Reprint feature is disabled, the ^SP command

 

 

 

 

 

can be used. In addition, when a received label format is canceled

 

 

 

 

 

prior to printing, the reprint function for the previous label is also

 

 

 

 

 

canceled. Refer to the ZPL II Programming Guide for additional

 

 

 

 

 

information.

 

 

 

 

 

Default: DISABLED

 

 

 

 

 

Range: ENABLED, DISABLED

 

 

 

 

 

To change the value shown:

 

 

 

 

 

1. Press the left or right oval to toggle between the options.

 

 

 

 

 

 

57512L-004 Rev. A

110PAX4/R110PAX4 User Guide

6/29/11