P100IH ISDN Router

Recv. Authen

This field sets the authentication protocol for incoming

 

 

calls. For security reason, setting authentication to none

 

 

is strongly discouraged. Options for this field are:

 

 

z CHAP/PAP - Your Prestige will try CHAP first, but

CHAP/PAP

 

 

PAP will be used if CHAP is not available.

 

 

 

 

z

CHAP – Use CHAP only.

CHAP

 

 

 

z

PAP – Use PAP only.

PAP

 

 

 

z

None – Your Prestige tries to acquire CHAP/PAP

None

 

 

 

 

first, but no authentication is required if CHAP/PAP

 

 

 

is not available.

 

Compression

Turn on/off Stac Compression. The default for this field

On

 

is Off.

Off

 

 

 

 

 

 

Mutual Authen

Some vendors, e.g., Cisco, require mutual

Yes/No

 

authentication, i.e., the node that initiates the call will

 

 

request a user name and password from the far end that

 

 

it is dialing to. If the remote node requires mutual

 

 

authentication, set this field to Yes.

 

O/G Login

Enter in the login name to be used to respond to the

 

 

peer’s authentication request.

 

O/G Password

Enter in the outgoing password to be used to respond to

 

 

the peer’s authentication request.

 

 

 

 

 

Multiple Link Options:

Max Trans Rate

Enter the maximum data transfer rate between your Prestige and the remote dial-in user. 64 - At most, one B channel is used. 128 - A maximum of two channels can be used. When the Prestige calls back to the remote dial-in user, the maximum data transfer rate is always

64.

64/128

Callback Budget

 

 

 

 

Management:

 

 

 

 

 

 

 

 

 

Allocated Budget (min)

 

This field sets the budget callback time for all the remote

Default = 0

 

 

 

dial-in users. The default for this field is 0 for no budget

 

 

 

 

control.

 

 

 

 

 

 

 

Period (hr)

 

This field sets the time interval to reset the above

 

 

 

 

callback budget control.

 

 

 

 

 

 

 

 

 

 

 

 

Dial-In Server Configuration

 

7-5

 

Page 93
Image 93
ZyXEL Communications 1001H manual Off, 64/128