Olicom 9600 Supply and Return Water Line Connections, Hard Water Lines, Flexible Water Lines

Page 26

9600 Compressor Installation, Operation, and Maintenance

CTI-CRYOGENICS

HELIX TECHNOLOGY CORPORATION

Supply and Return Water Line Connections

NOTE: The water used for cooling the Compressor must meet the specifications outlined in Section 1 - Compressor Description.

Hard Water Lines

1.Apply a light coating of standard plumbing thread sealant to the hard line pipe threads.

2.Install the Supply hard line into the INPUT connection on the rear panel of the Compressor. Tighten the fitting by hand.

3.Install the Return hard line into the OUTPUT connection on the rear panel of the Compressor. Tighten the fitting by hand.

CAUTION

Do not overtighten the ferrules. Damage to the input and output connector threads may occur.

4.Using a wrench, tighten the fittings.

5.Allow water to flow and check for leaks at the rear of the Compressor.

Flexible Water Lines

1.Apply a light coating of standard plumbing thread sealant to the barbed fitting threads.

2.Install the barbed fittings into the INPUT and OUTPUT connections on the rear panel of the Compressor.

CAUTION

Do not overtighten the barbed fittings. Damage to the INPUT and

OUTPUT connector threads may occur.

3.Using a wrench, tighten the barbed fittings.

4.Connect the Supply flexible water line to the INPUT barbed fitting and secure with a hose clamp.

5.Connect the Return flexible water line to the OUTPUT barbed fitting and secure with a hose clamp.

6.Allow water to flow and check for leaks at the rear of the Compressor.

P/N 8040540

3-3

Image 26
Contents Compressor Installation, Operation, Maintenance Instructions 8040540 Rev 12/2004Helix Page Table of Contents Operation InstallationMaintenance Figures Tables General Compressor Configurations9600 Compressor Description BenefitsSystem Documentation CTI-CRYOGENICS Helium Refrigeration System9600 Compressor Specifications DimensionsElectrical Input Specifications WeightCompressor Weight ElectricalCooling Water Specifications Cooling WaterGeneral Compressor Operating Specifications GeneralComponent Description 9600 Compressor Rear View Component LocationsSystem Circuit Breaker Power on IndicatorPower Inlet Control Circuit BreakerCryopump Electrical Outlet Return Gas CouplingCooling Water OUT Cryopump Electrical Outlet Pin AssignmentsCompressor Remote Connector Pin Assignments Cryopump Power Phase SwitchCompressor Remote Connector Multiple On-Board Cryopump Connections9600 Compressor Connected to Multiple On-Board Cryopumps Multiple Cryo-Torr Cryopump Connections 9600 Compressor Connected to Multiple Cryo-Torr CryopumpsCTI-CRYOGENICS Shipping Carton Inspection Unpacking and InspectionIntroduction Removal from Shipping CartonCompressor Shipping Carton ContentsCompressor Inspection Helium Static Pressure VerificationInstallation END Flexible Water Lines Supply and Return Water Line ConnectionsHard Water Lines Power Cable Preparation Electrical Connections9600 Compressor Circuit Breaker Terminals Cover Removed Phase Check Proceed with Cryopump Power Phase Switch SettingConnecting Connecting/Disconnecting Helium Flex LinesCryopump Power Phase Switch Setting Disconnecting Single On-Board Cryopump Connections Single On-Board Cryopump ConnectionsSingle Cryo-Torr Cryopump Installation Single Cryo-Torr Cryopump ConnectionsHelium Line Connections Power Cable Connections Multiple Cryo-Torr Cryopump Connections CTI-CRYOGENICS Recommended Multiple Cryo-Torr Cryopump Installation Alternative Multiple Cryo-Torr Cryopump Installation Static Helium System Pressure Verification Adjusting System Helium PressureOperation 9600 Compressor Helium Static ChargeCompressor Operation Replacement of Helium Circuit Components CTI-CRYOGENICS Suggested Maintenance Equipment MaintenanceScheduled Maintenance Adsorber Replacement Disconnecting Self Sealing CouplingsDate Reducing Helium Pressure 9600 Compressor Helium Pressure Control ComponentsIncreasing Helium Pressure Adding HeliumCTI-CRYOGENICS Product Information Appendix a Customer Support InformationMail Page Appendix B Flow Diagram Figure B-19600 Compressor Flow DiagramAppendix B Flow Diagram Technical Inquiries Appendix C Troubleshooting ProceduresTroubleshooting the Compressor Table C-1 Compressor Troubleshooting Procedures Compressor RemoteAppendix a to contact CTI-CRYOGENICS Appendix D Schematic Figure D-19600 Motor Drive Compressor Schematic