Olicom 9600 manual Increasing Helium Pressure, Adding Helium

Page 48

9600 Compressor Installation, Operation, and Maintenance

CTI-CRYOGENICS

HELIX TECHNOLOGY CORPORATION

To the value previously recorded in the Compressor Operation procedure in Section 4 - Operation if the compressor is ON.

3.Close the gas charge control valve and install the flare cap.

Increasing Helium Pressure

Use the following procedure to increase the helium pressure if the indicated pressure is below the appropriate value as shown in Table 4-1.

CAUTION

If helium is being added more than once every several months, check for leaks caused by improperly connected self-sealing connections or any mechanical joint within the Compressor.

Adding Helium

NOTE: You must obtain the normal system operating pressure from the Compressor Operation procedure in Section 4 - Operation in order to perform this procedure. If the normal system operating pressure is unknown, then shut the compressor OFF and perform the Static Helium System Pressure Verification procedure in Section 4 - Operation instead.

This procedure ensures that both the regulator and the charging line will be purged of air and that the air trapped in the regulator will not diffuse back into the helium bottle. For best results, CTI-CRYOGENICS suggests a dedicated helium bottle, regulator, and line, which are never separated, for adding helium.

NOTE: You are required to supply the helium charging line terminating in a 1/4-inch female flare fitting, and a two-stage pressure regulator rated at 0-3000/0-400 psig for this operation.

CAUTION

Use only 99.999% pure helium gas. Helium circuit contamination may result if a lower quality of helium is used.

1.Attach a regulator (0-3000/0-400 psig) and charging line to a helium bottle (99.999% pure).

NOTE: Do not open the bottle at this time.

P/N 8040540

5-5

Image 48
Contents Compressor Installation, Operation, Maintenance Instructions 8040540 Rev 12/2004Helix Page Table of Contents Installation MaintenanceOperation Figures Tables Compressor Configurations 9600 Compressor DescriptionGeneral BenefitsSystem Documentation CTI-CRYOGENICS Helium Refrigeration System9600 Compressor Specifications DimensionsWeight Compressor WeightElectrical Input Specifications ElectricalCooling Water Specifications Cooling WaterGeneral Compressor Operating Specifications GeneralComponent Description 9600 Compressor Rear View Component LocationsPower on Indicator Power InletSystem Circuit Breaker Control Circuit BreakerReturn Gas Coupling Cooling Water OUTCryopump Electrical Outlet Cryopump Electrical Outlet Pin AssignmentsCryopump Power Phase Switch Compressor Remote ConnectorCompressor Remote Connector Pin Assignments Multiple On-Board Cryopump Connections9600 Compressor Connected to Multiple On-Board Cryopumps Multiple Cryo-Torr Cryopump Connections 9600 Compressor Connected to Multiple Cryo-Torr CryopumpsCTI-CRYOGENICS Unpacking and Inspection IntroductionShipping Carton Inspection Removal from Shipping CartonShipping Carton Contents Compressor InspectionCompressor Helium Static Pressure VerificationInstallation END Supply and Return Water Line Connections Hard Water LinesFlexible Water Lines Power Cable Preparation Electrical Connections9600 Compressor Circuit Breaker Terminals Cover Removed Phase Check Proceed with Cryopump Power Phase Switch SettingConnecting/Disconnecting Helium Flex Lines Cryopump Power Phase Switch SettingConnecting Disconnecting Single On-Board Cryopump Connections Single On-Board Cryopump ConnectionsSingle Cryo-Torr Cryopump Installation Single Cryo-Torr Cryopump ConnectionsHelium Line Connections Power Cable Connections Multiple Cryo-Torr Cryopump Connections CTI-CRYOGENICS Recommended Multiple Cryo-Torr Cryopump Installation Alternative Multiple Cryo-Torr Cryopump Installation Adjusting System Helium Pressure OperationStatic Helium System Pressure Verification 9600 Compressor Helium Static ChargeCompressor Operation Replacement of Helium Circuit Components CTI-CRYOGENICS Maintenance Scheduled MaintenanceSuggested Maintenance Equipment Adsorber Replacement Disconnecting Self Sealing CouplingsDate Reducing Helium Pressure 9600 Compressor Helium Pressure Control ComponentsIncreasing Helium Pressure Adding HeliumCTI-CRYOGENICS Appendix a Customer Support Information MailProduct Information Page Appendix B Flow Diagram Figure B-19600 Compressor Flow DiagramAppendix B Flow Diagram Appendix C Troubleshooting Procedures Troubleshooting the CompressorTechnical Inquiries Table C-1 Compressor Troubleshooting Procedures Compressor RemoteAppendix a to contact CTI-CRYOGENICS Appendix D Schematic Figure D-19600 Motor Drive Compressor Schematic