IMPORTANT INFORMATION |
|
|
| ||
Gas type changing: |
|
| |||
From natural gas to propane | Figure 4 | ||||
It is necessary that all operations related with |
| ||||
installation, adjustment or adaptation | LP |
| |||
gas be performed by authorized personnel |
| ||||
of our Technical Service, and that the regulations |
| ||||
in force, as well as the requisites of the gas |
| ||||
companies, be followed. |
|
|
| ||
IMPORTANT: Before you begin, turn off the gas |
| ||||
and electricity supply to the appliance. |
| ||||
Before connecting up the appliance to the |
| ||||
installation, first check that it has been adjusted |
| ||||
for the type of gas that is to be supplied. Our |
| ||||
cooktops are delivered from factory prepared |
| ||||
to operate with the gas type indicated on the |
| ||||
specifications plate. |
|
|
|
| |
The propane gas tank must be equipped with its |
| ||||
own high pressure regulator in addition to the |
| ||||
pressure regulator supplied with this unit. |
| ||||
Supply Pressure |
|
|
|
| |
Natural Gas - 7" wc (17.5 mbar) minimum. |
| ||||
Propane Gas - 11" wc (27.4 mbar) minimum. | 7 mm. | ||||
The maximum supply pressure to this appliance | |||||
shall not exceed 14" water column (34.9 mbar). |
| ||||
This cooktop can be adapted to work |
|
| |||
with LP gas. To do so, the following |
|
| |||
procedures must be completed: |
|
| |||
A) Change of cooktop burner tips. (See table1). |
| ||||
| T ABLE 1 |
|
|
| |
| Burner data |
|
|
| |
The burner must be used with the | G A S | NATURAL | PROPANE |
| |
gases | indicated on the | TYPE |
| ||
specifications plate. |
|
|
|
| |
Gas pressure for use |
| 6” | 10” |
| |
Burner | Burner tip marker | BTU/hr | 133 | 95 |
|
Rapid | Consumption Rated | 10.000 | 10.000 | Figure 5 | |
| (Hs) |
|
|
| |
Burner | Burner tip marker | BTU/hr | 110 | 77 |
|
s e m i - | Consumption Rated | 7.000 | 7.000 |
| |
rapid | (Hs) |
|
|
|
|
B u r n e r | Burner tip marker |
| 98 | 69 |
|
Auxiliary | Consumption Rated | BTU/hr | 5.500 | 5.500 |
|
| (Hs) |
|
|
|
|
Large | Burner tip marker | BTU/hr | 106/81 | 72/55 |
|
Burner | Consumption Rated | 15.300 | 15.300 |
| |
|
|
|
| ||
1 - Remove the grates, covers and the main |
| ||||
body of the burner. |
|
|
|
| |
2 - Change the burner tips using a 7 mm socket |
| ||||
wrench and make sure that they are tightened all |
| ||||
the way in order to ensure that they are correctly |
| ||||
sealed. Figure 4. |
|
|
|
| |
The adjustment of primary air must not be performed |
| ||||
on these burners. |
|
|
|
| |
B) Reduced consumption adjustment of the cooktop |
| ||||
burner taps. |
|
|
|
| |
1 - Set the taps to the minimum setting. |
| ||||
2 - Remove the control knobs from the taps. |
| ||||
Figure 5. |
|
|
|
| |
|
|
|
|
| 19 |