GROUND FAULT CIRCUIT INTERRUPT (GFCI)
On HITACHI generator models (E43, E60, E71), all 20 Amp receptacles are protected by a ground fault circuit interrupt (GFCI). The GFCI shuts off the power to the receptacle when it senses small imbalances caused by current leakage to the ground.
CAUTION: Each GFCI should be tested for proper operation every time the generator is used.
TO TEST A GFCI:
Start the generator. Turn the idle control switch
Do not run generator until the problem can be corrected. To restore power to receptacle, push the RESET button in. If the RESET button pops out during operation, stop the generator and check the generator and equipment for defects.
REPLACEMENT PARTS | Fig.2 |
|
When servicing use only identical replacement parts.
Repairs should be conducted only by a Hitachi authorized service center.
USE PROPER EXTENSION CORD
Use only
Make sure your extension cord is in good condition. When using an extension cord, be sure to use one heavy enough to carry the current your product will draw. An undersized cord will cause a drop in line voltage resulting in loss of power and overheating. Be sure to choose a cord that will supply enough voltage to operate your tool or appliance. The tables below indicate appropriate guage for extension cords and the voltage drop caused by the use of extension cords, given different electrical loads.
MINIMUM GAGE FOR CORD SETS
Volts | Total Length of Cord in Feet (Meter) |
|
|
|
| ||
120V | 0 – 25 | 26 | – 50 | 51 – 100 | 101 | – 150 | |
| (0 – 7.6) | (7.9 | – 15.2) | (15.5 | – 30.5) | (30.8 | – 45.7) |
240V | 0 – 50 | 51 | – 100 | 101 | – 200 | 201 | – 300 |
| (0 – 15.2) | (15.5 | – 30.5) | (30.8 | – 61.0) | (61.3 | – 91.5) |
Ampere Rating |
| AWG |
| ||
More |
| Not More |
|
|
|
Than |
| Than |
|
|
|
0 – 10 | 16 | 16 | 14 | 14 | |
10 | – 13 | 16 | 16 | 14 | 12 |
13 | – 16 | 14 | 14 | 12 | 12 |
16 | – 25 | 12 | 12 | 12 | 10 |
25 | – 30 | 10 | 10 | 10 | Not Recommended |
WARNING: Avoid electrical shock hazard. Never use this generator with a damaged or frayed electrical cord or extension cord.
Inspect all electrical cords regularly. Never use in or near water or in any environment where electric shock is possible.