130TROUBLESHOOTING

Table 20 Fatal Error Messages (continued)

Error message

Significance

User Action

 

 

 

Ethernet selftest failed!

Hardware error during

Contact Technical Support.

 

initialization

 

 

 

 

HDLC selftest failed!

Hardware error during

Contact Technical Support.

 

initialization

 

 

 

 

I2C selftest failed!

Hardware error during

Contact Technical Support.

 

initialization

 

 

 

 

DRAM data bus test fail!

Hardware error

Contact Technical Support.

 

 

 

DRAM address bus test fail!

Hardware error

Contact Technical Support.

 

 

 

No MAC address for agent!

No MAC address on the

Contact Technical Support.

 

card in slot 1. This is the

 

 

card that provides

 

 

central management

 

 

for the VCN AC.

 

 

 

 

Boot-up and initialization are processes that occur when a card in an VCN AC slot is reset. Reset occurs when the user selects Reset board or Reset port from the menu system.

Telnet Connection Problems

Telnet connection problems take two forms:

The user cannot connect the management computer to the management agent; refer to Inability to Connect

An established Telnet session is broken; refer to Broken Session.

Inability to Connect An inability to connect can have a number of causes which should be verified. Some problems are not location dependent while other problems are.

Perform these location independent checks:

You are using a good cable.

Your Telnet terminal emulation is VT100.

You are using the correct IP address of the management agent.

Your login ID and password are correct.

Another Telnet session does not exist. Only one Telnet session is supported.

Page 130
Image 130
3Com DSA-3CV1100-02 service manual Telnet Connection Problems