116 CHAPTER 7: RECONFIGURING A VCX SERVER
Sample VCX Reconfiguration Script (continued)
The SNMP 'write' community string configured in the UPS is required. (For
security reasons, it is recommended that the default value provided by the
UPS be changed.)
UPS 'write' community string : private
The string you enter here must match the SNMP write community string
configured on the UPS.
Enter the IP address assigned to the second UPS's management card or
Ethernet interface. Note: The UPS must already be configured with this
address.
Second UPS IP address : 10.230.67.51
The SNMP 'write' community string configured in the second UPS is required.
Second UPS 'write' community string : private
The string you enter here must match the SNMP write community string
configured on the UPS.
The VCX system polls the UPS at regular intervals to get status
information. A shorter interval makes the system more responsive to UPS
status changes, but consumes more network bandwidth. The default value
should work for most systems.
Polling Frequency (seconds) : 30
The default polling interval is 30 seconds.
A 'low battery' condition is reached when the battery charge reaches a
defined threshold percentage.
Low Battery Threshold (%) : 25
Enter UPS battery threshold charge allowed before starting a shutdown
of the VCX system. The threshold charge is expressed as a percentage of
remaining battery power. The default is 25%. The range is from 25% to
75%.
Do you wish to change any of the UPS Monitoring parameters? [N] : n