21.

Specifications

 

 

 

 

Analog Input and A/D Conversion

 

 

Input sensitivity

 

 

Up to 0.25 mV/division

 

 

Input signal range

 

-1 mV ~ 15 mV

 

 

Load cell excitation voltage

5V DC

 

5%, 60 mA with sense voltage input

 

 

 

 

 

 

 

 

Load cell drive capacity

Maximum 4 x 350 W load cells

 

 

Temperature

 

Zero

 

 

(0.2 mV + 0.0008 % of zero adjustment voltage)/ (typ.)

 

 

coefficient

 

 

 

 

 

 

 

 

 

 

Span

 

 

0.0008%/ of reading (typ.)

 

 

 

 

 

 

 

 

 

Non-Linearity

 

0.01 % of full scale

 

 

Maximum input noise

 

Less than 0.4 mVp-p

 

 

Input impedance

10 MW or more

 

 

A/D conversion method

 

Integrating dual slope type

 

 

A/D resolution count

40000 counts

 

 

A/D conversion rate and

Approximately 10 times/s (unstable), 5 times/s (stable)

display update rate

 

 

 

 

 

 

 

Maximum display resolution

20000 (permissible 40000)

 

 

 

 

Digital Section

 

 

 

 

 

 

 

Measurement display

7 segment, Vacuum fluorescent display tube

 

 

 

 

Character color

Cobalt-blue

 

 

 

 

 

 

Character height

 

20 mm

 

 

 

 

 

 

 

 

 

Minus sign, Zero point, Stable, Net, Preset tare value,

State indicator Symbol

Storing accumulation data, Percentage,

 

 

 

 

 

 

 

Various state indicator (triangle1, 2,3)

 

 

 

 

 

 

 

 

 

 

 

 

Character color

Cobalt-blue

 

 

Comparison result

HI, OK, LO

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Character color

Red for HI and LO, Green for OK

 

 

Unit

 

kg, g, t (lb, oz, lb-oz / catty, tl, catty-tl: depends on the region)

 

 

 

 

Character color

Cobalt-blue

 

 

 

 

Interface

 

 

 

 

 

 

 

 

RS-232C interface

Serial interface for communication (D-Sub 9P)

RS-422/485 interface

Serial interface for communication, control (terminal block)

Current Loop output

 

20mA, Passive type (DIN 8P)

 

 

Analog output

 

4-20mA, free scaling output (terminal block)

External Control Input

 

3 (or 1) contact input terminals, selected functions (DIN 8P)

 

 

 

 

 

 

 

3 point (DIN 8P or terminal block)

 

 

 

 

 

 

 

 

 

Capacity: 50V AC/DC, maximum current 100mA (resistive load)

Relay output

 

Comparison mode selection

 

 

 

 

 

 

 

 

 

HiHi, Hi, OK, Lo, LoLo output for limit comparison

 

 

 

 

 

 

 

Zero band, preliminary, free fall, final for setpoint comparison

 

 

Printer

 

 

 

 

 

 

 

 

Built-in printer

 

5 x 7 dot matrix type, 16 digits per line

 

 

 