SAFETY

INTRAC-305

1.SAFETY

WARNING

POSSIBLE LETHAL POTENTIALS EXIST WITHIN THIS EQUIPMENT

THE COVERS SHOULD NOT BE REMOVED EXCEPT BY QUALIFIED PERSONNEL.

SWITCH OFF POWER AND ISOLATE SUPPLY BEFORE REMOVING COVERS.

IF IT IS NECESSARY TO OPERATE THE EQUIPMENT WITH THE COVERS REMOVED FOR SERVICING PURPOSES ALL NECESSARY PRECAUTIONS SHOULD BE TAKEN TO PROTECT AGAINST ELECTRIC SHOCKS

ELECTRICAL

Fusing The standard unit is protected by a user replacable fuse in the live/phase power supply line.

Care should be taken to ensure that the power cable is correctly connected to the power source such that the live/phase connection of the INTRAC is connected to the live/phase terminal of the supply.

When replacing the fuse be sure to do so with one of the correct value and type.

The Dual Redundant power supply version is protected by separate board mounted fuses on each power supply. These are not user replaceable.

Earthing It is important that the electrical supply has a good and proper earth and that earth is connected through to the INTRAC-305 via the power cable.

Battery Disposal The processor board contains a Nickel Cadmium (NiCd) or Lithium battery. These elements are toxic. The battery should be disposed of according to national requirements.

DO NOT PLACE IN NORMAL GARBAGE OR IN A FIRE.

RF I/P Connector for IBR-L18Vdc may be present on the inner of the N-Type connector to power the LNB/BDC. This voltage can be removed by unplugging connector J41.

Emergency Stop There is a latching emergency stop switch on the INTRAC front panel. Pressing this switch will remove power from the antenna drive motors and the INTRAC will enter Standby mode. To restore drive the switch should be rotated clockwise (CW) and Auto Continue selected.

Page 10

INTRAC-305 MANUAL - Issue 3.2

© Advantech AMT Ltd

Page 10