7

INTRAC-305

FAULT FINDING

If all the angles are changing the fault is on the Interface PCB.

wrong angle displayed If the displayed angle changes to be near 0° or 90° it is probable that one of the two return signal circuits from the resolver is broken or the resolver itself is faulty.

If the displayed angle changes to any angle other than near 0° or 90° the fault is on the Interface PCB.

angle doesn’t change If the displayed angle doesn’t change when the antenna is

when antenna is moved being driven first ensure that the antenna is actually moving in the relevant plane. Select Manual Mode and drive the antenna in the appropriate direction and either check that the beacon level changes or actually look at the antenna.

If the antenna moves but the displayed angle does not change the problem is the connection of the resolver to the antenna.

No Antenna Drive

Check that the LEDs in the Manual Control keys illuminate

 

 

 

when antenna drive is commanded. If not the fault is on the

 

 

 

Interface PCB.

 

 

 

 

 

 

 

 

 

 

 

 

The Motor Controls connector (50-way D-type) on INTRAC

 

 

 

rear panel outputs +12v and ground to for each drive signal.

 

 

 

The +12v and ground levels are switched to the approriate

 

 

 

pins of the connector by relays. One relay switches +12v for

 

 

 

all Az drive commands, another does so for all El drive

 

 

 

 

commands and a third for Pol drive. The ground level is

 

 

 

switched by changeover relays, one does Az West or East,

 

 

 

another Az Fast or Slow, another El Down or Up, another El

 

 

 

Fast or Slow and another for Pol CCW or CW.

 

 

 

 

 

 

The table below indicates across which two pins of the 50

 

 

 

way connector there should be 12v for each drive condition.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Direction

 

Az

Az

 

Az

Az

El

 

El

El

El

 

Pol

Pol

 

& Speed

 

East

West

 

Fast

Slow

Down

 

Up

Fast

Slow

 

CCw

Cw

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

+12 volts

 

18

19

 

20

21

22

 

23

24

25

 

26

27

 

Ground

 

1

2

 

3

4

5

 

6

7

8

 

9

10

 

 

 

 

 

 

 

 

 

 

 

 

 

 

example

Elevation Up Fast -

there should be 12v across pins 23 & 6

 

 

 

(El Up) and across 24 & 7 (El Fast).

 

 

 

 

 

 

If the drive signals from the INTRAC are correct the fault lies with the Motor Drive Cabinet, the antenna drive motors or the intervening wiring.