FINE TUNE - sense

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Function

Current Mode

 

 

Tracking

Standby

Control State

 

 

Local

Beac Freq

11.452000 GHz

 

Beac Level

-10.05

 

dB

 

El

Angle

25.37o

 

 

 

Home

Az

Angle

210.50oo

 

 

 

Pol

Angle

27.4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Resolver Sense:

 

 

 

 

 

 

 

 

 

 

Change

 

 

 

 

 

 

 

 

 

 

Azimuth

>true<

 

Resolver

 

Elevation

 

inv

Sense

 

 

 

 

Pol Angle

 

inv

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Next

 

 

 

 

 

 

 

 

 

Field

Press EN to accept sense settings

1

2

3

4

5

6

puts the antenna control system into STANDBY mode and skips to the HOME menu

skips to the Home (root) menu

(not used)

toggles the highlighted parameter between ‘true’ and ‘inv’

(not used)

moves the highlight box to the next field in the current menu

Path

HOME - FUNCTION - SYSTEM SETUP -

 

MENU KEY 6 (x2) - ENTER

or

From Models or Configuration

 

SYSTEM SETUP - MENU KEY 6 (x2) - ENTER

Description

This menu allows the “sense” of the Azimuth, Elevation and

 

Polarisation resolvers to be inverted. This is necessary to

 

allow for different mounting arrangements for the resolvers.

 

Use Menu Key 6 to step the edit highlight through the three

 

angles. Use Menu Key 4 (Change Resolver Sense) to toggle

 

between “true” and “inv.”

 

Pressing ENTER accepts the settings and moves on to the

 

“FINE TUNE - Offsets” menu. (see next page)