FINE TUNE - sense
Resolver Sense:
Azimuth >true<
Elevation inv
Pol Angle inv
1
2
3
4
5
6
(not used)
toggles the highlighted parameter
between ‘true’ and ‘inv’
(not used)
moves the highlight box to the next field
in the current menu
Current Mode Tracking
Control State Local
Beac Freq 11.452000 GHz
Beac Level -10.05 dB
El Angle 25.37o
Az Angle 210.50o
Pol Angle 27.4 o
Function
Press EN to accept sense settings
Next
Field
Change
Resolver
Sense
Home
Standby puts the antenna control system into
STANDBY mode and skips to the HOME
menu
skips to the Home (root) menu
Path HOME - FUNCTION - SYSTEM SETUP -
MENU KEY 6 (x2) - ENTER
or From Models or Configuration
SYSTEM SETUP - MENU KEY 6 (x2) - ENTER
Description This menu allows the “sense” of the Azimuth, Elevation and
Polarisation resolvers to be inverted. This is necessary to
allow for different mounting arrangements for the resolvers.
Use Menu Key 6 to step the edit highlight through the three
angles. Use Menu Key 4 (Change Resolver Sense) to toggle
between “true” and “inv.”
Pressing ENTER accepts the settings and moves on to the
“FINE TUNE - Offsets” menu. (see next page)