INTRAC-305

OPERATION

BEACON THRESHOLD

Current Mode

Tracking

 

Control State

Local

 

Beac Freq

11.452000 GHz

Beac Level

-10.05

 

dB

El

Angle

25.37o

 

Az

Angle

210.50o

 

Pol

Angle

27.4

o

 

 

 

 

 

 

Set Level:

-14.12

dB

 

 

 

Press EN to accept selection

Function

Standby

Home

Models

Config

System

Setup

1

2

3

4

5

6

puts the antenna control system into STANDBY mode and skips to the HOME menu

skips to the Home (root) menu

skips to the Models menu

skips to the Config menu

skips to the System Setup menu

(not used)

Path

HOME - FUNCTION - MENU KEY 6 (x8) - ENTER

or

From Models or System Setup

 

CONFIG - MENU KEY 6 (x8) - ENTER

Description

On this screen the beacon signal strength at which the

 

beacon level alarm trips is set.

 

If the tracking signal level falls below the value set here the

 

INTRAC-305 considers the tracking signal receiver to have

 

lost lock on the beacon.

 

Edit the value in the “Set Level” box using the numeric

 

keypad. The & move the cursor.

Note

The only function of the beacon level alarm is to operate a

 

relay for external use. It is not used by the INTRAC algorithm

 

and, when it occurs in isolation without an alarm from the

 

IBR-L, has no effect on the INTRAC operation or mode.

© 2011 Advantech Wireless

INTRAC-305 MANUAL - Issue 3.2

Page 27