INSTALLATION

INTRAC-305

Serial Port RS422/423 Setting Setting the Serial Ports to RS422 or RS423 is achieved by positioning the rear panel ribbon cables and by link positions. The table below shows the positions.

 

INTRACTM 305 Serial Port Configuration - Connector & Link Positions

 

 

 

 

 

 

 

 

 

 

 

INTRAC-305

 

 

RS423

RS422

 

 

 

Ribbon Cable

Link Position

Ribbon Cable

Link Position

 

 

Serial Port

 

 

 

 

position.

 

position.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Test Port 1

 

J12

 

J44 Front

J15

J44 Rear

 

 

Test Port 2

 

J11

 

J46 Front

J14

J46 Rear

 

 

 

 

 

 

 

 

 

 

Serial Port Usage

The three ports can be used to connect a Remote Control

 

 

 

Terminal, to monitor diagnostic data or to monitor angle data.

 

 

 

The specific uses for each port are:-

 

 

 

Remote Port

A Remote Control and Monitoring Terminal may be

 

 

 

connected to this port.

 

 

 

 

 

 

Diagnostic data can be monitored by selecting “Diagnostics

 

 

 

On” in the “Function - Configuration” menu. Remote control

 

 

 

of the INTRAC is achieved only if “Diagnostics Off” is selected

 

 

 

in the Configuration menu.

 

 

 

Test Port 1

Diagnostic data is also available at this port together with

 

 

 

Angles data. The selection between Diagnostics and Angles

 

 

 

is made by Menu Key 4 on the “Function - Configuration”

 

 

 

menu. The key switches between “Test Port-1 Diags” and

 

 

 

“Test Port-1 Angles”

 

 

 

 

Test Port 2

This port is for a Remote Control Terminal only.

 

 

 

The Remote Port allows one PC to be used as a remote

 

 

 

control unit and as a diagnostics monitoring unit. However it

 

 

 

cannot do both at the same time.

 

 

 

Note

For correct remote control of the INTRAC-305 via the

 

 

 

Remote Port Diagnostics must be set to OFF. Diagnostic

 

 

 

data can be monitored during remote operation by using a

 

 

 

second PC connected to Test Port 1.

 

 

Page 72

INTRAC-305 MANUAL - Issue 3.2

©2011 Advantech Wireless

Page 84
Image 84
Advantech INTRAC-305 user manual Data can be monitored during remote operation by using a, Second PC connected to Test Port