INSTALLATION INTRAC-305
Page 72 INTRAC-305 MANUAL - Issue 3.2 ©2011 Advantech Wireless
Serial Port RS422/423 Setting Setting the Serial Ports to RS422 or RS423 is achieved by
positioning the rear panel ribbon cables and by link positions.
The table below shows the positions.
INTRACTM 305 Serial Port Configuration - Connector & Link Positions
RS423
RS422
Ribbon Cable
position.
Link Position
Ribbon Cable
position.
Link Position
Test Port 1
J12
J44 Front
J15
J44 Rear
Test Port 2
J11
J46 Front
J14
J46 Rear
Serial Port Usage The three ports can be used to connect a Remote Control
Terminal, to monitor diagnostic data or to monitor angle data.
The specific uses for each port are:-
Remote Port A Remote Control and Monitoring Terminal may be
connected to this port.
Diagnostic data can be monitored by selecting “Diagnostics
On” in the “Function - Configuration” menu. Remote control
of the INTRAC is achieved only if “Diagnostics Off” is selected
in the Configuration menu.
Test Port 1 Diagnostic data is also available at this port together with
Angles data. The selection between Diagnostics and Angles
is made by Menu Key 4 on the “Function - Configuration”
menu. The key switches between “Test Port-1 Diags” and
“Test Port-1 Angles”
Test Port 2 This port is for a Remote Control Terminal only.
The Remote Port allows one PC to be used as a remote
control unit and as a diagnostics monitoring unit. However it
cannot do both at the same time.
Note For correct remote control of the INTRAC-305 via the
Remote Port Diagnostics must be set to OFF. Diagnostic
data can be monitored during remote operation by using a
second PC connected to Test Port 1.