TECHNICAL DESCRIPTION |
|
|
| IESS Minutes Interval | range: 0 to 59 |
| IESS Days Validity | range: 0 to 28 |
| IESS Sat LM0 | range: 0 to 360 deg |
| IESS Sat LM1 | range: |
| IESS Sat LM2 | range: |
| IESS Sat LONC | range: |
| IESS Sat LONC1 | range: |
| IESS Sat LONS | range: |
| IESS Sat LONS1 | range: |
| IESS Sat LATC | range: |
| IESS Sat LATC1 | range: |
| IESS Sat LATS | range: |
| IESS Sat LATS1 | range: |
| IESS Sat LONG170 | range: 0 to 360 deg |
| IESS Sat LAT170 | range |
| Also required to be set are the IESS Az & El offsets which are | |
| input on the Function - System Setup - Station Coordinates | |
| menu screen. |
|
| The IESS Epoch defines the time instant at the start of the | |
| period of the IESS data. The IESS Minutes Interval defines the | |
| period in minutes between pointing updates in Program Track | |
| mode. The IESS Days Validity (normally 7) defines the period | |
| of validity of the data. The INTRAC will accept and use the | |
| data two days either side of the validity period. | |
| The parameters IESS Sat (LM0, LM1, LM2, LONC, LONC1, | |
| LONS, LONS1, LATC, LATC1, LATS, LATS1) are the IESS- | |
| 412 | |
| (LONG170, LAT170) are the | |
| 170hr parity check. |
|
Note | The data ranges shown above as +/- 9.99 actually accept more | |
| than two places of decimals. | |
Note | The LMO value is given in the range | |
|
the front panel. (It can accept them from the
Page 60 | © 2011 Advantech Wireless |