4.3.2 ROM (Read-Only Memory)
Read-only memory contains default values that are set at the factory. They
are called default values because they are stored in ROM and cannot be
changed. You can load these default values into operating memory while
in Menu Mode using the procedure shown in Table 4–3.
NOTE: Default values loaded from ROM are temporary values, and are
affected if the printer receives a reset command or is powered off. If you
want to retain the default values, you must save them in NVRAM (see
Section 4.3.3).

Table 4–3: Recalling Factory Default Values from ROM

Operation Display Reads
1. Press OnLine to place the
printer off line.
— The On Line indicator
shuts off.
00 READY
2. Press Menu toplace the
printer in Menu Mode. FONT/FEED LAYOUT
3. Press once. LOAD<–ROM FONT/F
4. Press Enter to
load the default
values from ROM.
OK (momentarily)
LOAD<–ROM FONT/F
5. Press OnLine to place
the printer on line.
— The On Line indicator
lights.
00 READY
4–8 DEClaser 2100 Printer Operator’s Guide