x510DP-52GTX Installation Guide
4.With a
± 0.039 in.), as shown in Figure 33 on page 71.
Warning
Do not strip more than the recommended amount of wire. Stripping more than the recommended amount can create a safety hazard by leaving exposed wire on the terminal block after installation. E10
8mm ±1mm |
(0.31in. ±0.039in.) |
Figure 33. Stripped Wire
5.Insert the power supply ground wire into the middle connector of the DC terminal and tighten the connection with a flathead screwdriver, as shown in Figure 34 on page 71.
Warning
When installing this equipment, always ensure that the power supply ground connection is installed first and disconnected last. E11
PWR250R | 0VDC |
|
| |
| 6A |
|
| |
| OUTPUT PO | WER |
| |
| FAULT |
| ||
AT- |
|
|
|
|
|
|
| FOR CENTRALIZED DC POWER | CONNECTION, INS TALL ONLY IN A RESTRICTED AREA. |
|
|
|
| 2269 |
Figure 34. Inserting Wires into a DC Terminal Block
71