Allied Telesis AT-X510DP-52GTX manual Inserting Wires into a DC Terminal Block

Models: AT-X510DP-52GTX

1 129
Download 129 pages 55.29 Kb
Page 71
Image 71

x510DP-52GTX Installation Guide

4.With a 14-gauge wire-stripping tool, strip the three wires in the tray cable coming from the DC input power source to 8mm ± 1mm (0.31 in.,

± 0.039 in.), as shown in Figure 33 on page 71.

Warning

Do not strip more than the recommended amount of wire. Stripping more than the recommended amount can create a safety hazard by leaving exposed wire on the terminal block after installation.  E10

8mm ±1mm

(0.31in. ±0.039in.)

Figure 33. Stripped Wire

5.Insert the power supply ground wire into the middle connector of the DC terminal and tighten the connection with a flathead screwdriver, as shown in Figure 34 on page 71.

Warning

When installing this equipment, always ensure that the power supply ground connection is installed first and disconnected last.  E11

PWR250R

40-6

0VDC

 

 

 

6A

 

 

 

OUTPUT PO

WER

 

 

FAULT

 

AT-

 

 

 

 

 

 

 

FOR CENTRALIZED DC POWER

CONNECTION, INS TALL ONLY IN A RESTRICTED AREA.

 

 

 

 

2269

Figure 34. Inserting Wires into a DC Terminal Block

71

Page 71
Image 71
Allied Telesis AT-X510DP-52GTX manual Inserting Wires into a DC Terminal Block