Allied Telesis AT-X510DP-52GTX manual Confirming Status VCStack Feature

Models: AT-X510DP-52GTX

1 129
Download 129 pages 55.29 Kb
Page 81
Image 81

x510DP-52GTX Installation Guide

Confirming the

Status of the

VCStack Feature

Another way to confirm that VCStack is disabled on the switch is by displaying the status of the last two SFP+ slots on the switch. These are slots 51 and 52. If VCStack is disabled, you should be able to display the status of the slots even when they do not have transceivers. If VCStack is not disabled, the switch displays a message that it cannot find the slots. To view the status of the stacking slots, perform this procedure:

1.Start a management session on the switch. For directions, refer to “Configuring the Switch for Stand-alone Operations” on page 78.

2.Log on to the switch. The default user name is “manager” and the password is “friend”.

3.From either the User Exec mode or Privileged Exec mode, enter the SHOW INTERFACE command to display the status of one of the last two SFP+ slots on the switch. For example, enter this command to view the status of slot 51:

show interface port1.0.51

If VCStack is disabled, the switch displays the status of the designated slot. An example is shown in Figure 45 on page 81.

awplus>show interface port1.0.51 Interface port1.0.51

Scope: both

Link is DOWN, administrative state is UP Thrash-limiting

Status Not Detected, Action learn-disable, Timeout 1(s) Hardware is Ethernet, address is 0015.774f.ed30

index 5051 metric 1 mru 1500

configured duplex auto, configured speed auto, configured polarity auto

<UP,BROADCAST,MULTICAST>

SNMP link-status traps: Disabled

input packets 0, bytes 0, dropped 0, multicast packets 0

output packets 0, bytes 0, multicast packets 0 broadcast packets 0 Time since last state change: 0 days 00:42:49

Figure 45. Status of a Stacking Slot When VCStack is Disabled

81