Allied Telesis AT-X510DP-52GTX manual Maximum Distance Cable Requirements Port Pinouts

Models: AT-X510DP-52GTX

1 129
Download 129 pages 55.29 Kb
Page 21
Image 21

Maximum

Distance

Cable Requirements

Port Pinouts

x510DP-52GTX Installation Guide

The MDI and MDI-X settings do not apply when ports are operating at 1000 Mbps.

The ports have a maximum operating distance of 100 meters (328 feet).

The cable requirements of the ports are given in Table 1.

Table 1. Twisted Pair Cable for the 10/100/1000Base-T Ports

Cable Type

10Mbps

100Mbps

1000Mbps

 

 

 

 

 

 

 

 

Standard TIA/EIA 568-B-

Yes

Yes

No

compliant Category 3 shielded

 

 

 

or unshielded cabling with 100

 

 

 

ohm impedance and a

 

 

 

frequency of 16 MHz.

 

 

 

 

 

 

 

Standard TIA/EIA 568-A-

Yes

Yes

Yes

compliant Category 5 or TIA/

 

 

 

EIA 568-B-compliant Enhanced

 

 

 

Category 5 (Cat 5e) shielded or

 

 

 

unshielded cabling with 100

 

 

 

ohm impedance and a

 

 

 

frequency of 100 MHz.

 

 

 

 

 

 

 

Standard TIA/EIA 568-B-

Yes

Yes

Yes

compliant Category 6 or 6a

 

 

 

shielded cabling.

 

 

 

 

 

 

 

Refer to Table 11 on page 125 and Table 12 on page 126 for the port pinouts of the 10/100/1000Base-T twisted pair ports.