x510DP-52GTX Installation Guide
Note
The User Exec mode is the first level in the command mode interface. For complete information on the modes and commands, refer to the Software Reference: AlliedWare Plus Operating System for x510 Series.
3.Enter the SHOW STACK command to display the status of the VCStack feature. Figure 40 is an example of the command.
awplus> | show stack |
|
|
|
| |
Virtual | Chassis Stacking summary information |
|
| |||
ID | Pending ID | MAC address | Priority | Status | Role | |
1 | - |
| 0015:774f:ed30 | 128 | Ready | Active Master |
Operational Status |
| Standalone Unit |
| |||
Stack | MAC address | 0015:774f:ed30 |
|
|
| |
awplus(config)# |
|
|
|
|
Figure 40. SHOW STACK Command
4.Review the following items:
If the Operational Status is “Stacking Hardware Disabled,” the VCStack feature is already disabled on the switch and the SFP+ stacking slots may be used with regular SFP or SFP+ transceivers.
If the Operational Status is “Standalone Unit,” as shown in Figure 40 on page 79, the VCStack feature is active on the unit. You must disable it by performing the steps in the rest of this procedure before you can use the SFP+ stacking slots with regular SFP or SFP+ transceivers. The reason the status says “standalone” is because the switch considers itself a stack of one switch.
5.Move to the Global Configuration mode by entering the ENABLE and CONFIGURE TERMINAL commands, as shown in Figure 41.
awplus> enable
awplus# configure terminal
Enter configuration commands, one per line. End with CNTL/Z awplus(config)#
Figure 41. Moving to the Global Configuration Mode
6.To. disable the VCStack feature on the switch, enter the NO STACK ENABLE command, which has this format:
no stack id enable
79