Troubleshooting

 

Symptom Charts/Power - 6

 

 

you remove

1

Connect power adapter to unit for 24 hours to see if backup

 

After

battery, some Control

 

battery is just depleted. (It takes approximately 48 hours to

Panel settings are

2

fully charge the backup battery.)

different

Check backup battery cable and connections.

 

 

 

3

Replace backup battery.

 

 

 

4

Replace PMU card.

 

 

 

5

Replace cable from PMU to I/O logic board.

 

 

 

6

Replace I/O logic board.

Power adapter is

1

Verify that power adapter is connected correctly and the

plugged in, but

2

power cord is plugged solidly in the adapter.

Control Strip doesn’t

Verify that there is power at the outlet.

indicate adapter is

3

Try known-good power adapter.

connected

4

Replace sound card.

 

 

 

5

Replace PMU card.

 

 

 

6

Replace PMU cable.

 

 

 

7

Replace I/O logic board.