Troubleshooting

 

 

Symptom Charts/Power - 9

 

 

won’t charge

1

Reset power manager (shift-Fn-Ctrl-Pwr button).

 

Battery

 

 

 

2

Try battery in opposite expansion bay.

 

 

 

3

Verify EMI shield has no contact with outer shield of the

 

 

 

 

power adapter (refer to Additional Procedures, “Right I/O

 

 

 

 

Wall EMI Shield”).

 

 

 

Caution:

When reinstalling the top case, ensure the EMI shield

 

 

 

will not make contact with the outer shield of the AC power

 

 

 

adapter. Otherwise when the power adapter is plugged in, the unit

 

 

 

will not charge the battery during use.

4Try known-good battery. Repeat once.

5Replace charge card.

6Replace PMU board.

7Replace power supply card.

8Replace I/O logic board.

Page 66
Image 66
Apple M4753 manual Verify EMI shield has no contact with outer shield