Bosch Appliances TTCAN Event Driven Transmit Message, Time Slaves, Potential Time Masters

Models: TTCAN

1 77
Download 77 pages 249 b
Page 65
Image 65

TTCAN

User’s Manual

Revision 1.6

manual_about.fm

TxRqst and RmtEn may never be set for a periodic transmit message. To enable the transmission of a periodic message inside an Exclusive Time Window, TxRqst has to be set to ‘0’ and NewDat has to be set to ‘1’. The message will be transmitted each time its Tx_Trigger(s) become(s) active, neither TxRqst nor NewDat will be changed. MSC will be updated according to the success of the transmissions.

The application program has to ensure that all data of the periodic transmit messages are valid before the time triggered communication is started.

5.1.4.3 Event Driven Transmit Message

The configuration of an event driven transmit message for the transmission inside an Arbitrating Time Window is the same as for “Event driven Communication”. The combination of TxRqst=‘0’ and NewDat=‘1 is illegal for an event driven transmit message.

The Message Objects for event driven transmit messages may be managed dynamically, several messages with different identifiers may share the same Message Object.

5.2 TTCAN Schedule Initialisation

The synchronisation to the TTCAN message schedule starts when the Operation Mode is switched from Configuration Mode to either Strictly Time Triggered Operation or to Event Synchronised Time Triggered Operation. All nodes will start with Cycle Time=0 at the beginning of their Trigger List, SyncSt will be 0 (out of synchronisation), and no transmission will be enabled with the exception of the Reference Message. Nodes in mode Event Synchronised Time Triggered Operation will ignore Tx_Ref_Trigger and Watch_Trigger and will use instead Tx_Ref_Trigger_Gap and Watch_Trigger_Gap until the first Reference Message decides whether a Gap is active.

5.2.1 Time Slaves

After configuration, a Time Slave will ignore its Watch_Trigger and Watch_Trigger_Gap when it did not receive any message before reaching the Watch_Triggers. When it reaches Initial_Watch_Trigger (not part of the Trigger List, defined as maximum of Cycle Time), IWT in the Interrupt Vector register is set, the FSE is frozen, and the Cycle Time will become invalid, but the node will still be able to take part in CAN bus communication (to give acknowledge or to send error flags). The first received Reference Message will restart FSE and Cycle Time.

When a Time Slave has received any message but the Reference Message before reaching the Watch_Triggers, it will assume a Fatal Error (Error Level 3), set WTr in the Interrupt Vector register, switch off its CAN bus output, and enter the Bus Monitoring Mode. In the Bus Monitoring Mode, it is still able to receive messages, but it cannot send any dominant bits and therefore cannot give acknowledge. The Fatal Error state can be left via a re-configuration.

When no error is encountered during synchronisation, the first Reference Message will put SyncST to Synchronising and the second will put it (depending on its Next_is_Gap bit) into In_Schedule or In_Gap, enabling all Tx_Triggers and Rx_Triggers.

5.2.2 Potential Time Masters

After configuration, a Potential Time Master will start the transmission of a Reference Message when it reaches its Tx_Ref_Trigger (or its Tx_Ref_Trigger_Gap when in mode Event Synchronised Time Triggered Operation). It will ignore its Watch_Trigger and Watch_Trigger_Gap when it did not receive any message or transmit the Reference Message successfully before reaching the Watch_Triggers (assumed reason: All other nodes still in

BOSCH

- 65/77 -

11.11.02

Page 65
Image 65
Bosch Appliances TTCAN user manual Event Driven Transmit Message, Time Slaves, Potential Time Masters