4. ASSEMBLY

Refer to “4-20. Work clamp arm mechanism (Applying grease)”

3433Q

Refer to “4-20. Work clamp arm mechanism (Applying grease)”

3434Q

Carry out the adjustment in “5-24. Adjusting the home position” before installing the feed plate.

Work clamp arm assembly installation position

(A)When using solenoid-type work clamp S Pneumatic-type

(B)When using solenoid-type work clamp L

3435Q

11.Feed bracket cover

12.Feed plate

13.Plain washers [2 pcs]

14.Bolts [2 pcs]

15.Work clamp arm assy

16.Washers [2 pcs]

17.Bolts [2 pcs]

18.Cylinder support [Pneumatic spec. only]

19.Bolts [2 pcs: Pneumatic spec. only]

After installing, carry out test feeding and check that the needle hole is inside the work clamp and the feed plate frame. If the needle hole is not inside the frame, adjust the position of the work clamp arm assembly and feed plate.

93

KE-430B, 430C series